Novel Black-Box Arc Model Validated by High-Voltage Circuit Breaker Testing
IEEE Transactions on Power Delivery, 2018In this paper, we present a new black-box arc model that was validated using tests with short-line fault interruption of high-voltage circuit breakers.
T. Ohtaka +2 more
semanticscholar +1 more source
IEEE Transactions on Power Apparatus and Systems, 1964
A compound circuit is described for development and acceptance testing of circuit-breaker modules and circuit breakers up to 50,000 equivalent 3-phase module mva (megavoltamperes). The paper discusses high-current-source voltage requirements, synchronization of high-voltage-source application with final current zero, and high-voltage-source impedance ...
T. W. Liao +3 more
openaire +1 more source
A compound circuit is described for development and acceptance testing of circuit-breaker modules and circuit breakers up to 50,000 equivalent 3-phase module mva (megavoltamperes). The paper discusses high-current-source voltage requirements, synchronization of high-voltage-source application with final current zero, and high-voltage-source impedance ...
T. W. Liao +3 more
openaire +1 more source
Fault Analysis of 220kV High Voltage Circuit Breaker
2019 6th International Conference on Information Science and Control Engineering (ICISCE), 2019As the switch and protection equipment of power system, the reliable work of high voltage circuit breaker is of great significance to the safe operation of the whole power system. Mechanical fault is still the main fault of high voltage circuit breaker.
Lin Yan, Wei Wang
openaire +1 more source
High-Voltage Circuit Breaker Fault Diagnosis Model Based on Coil Current and KNN
Prognostics and System Health Management Conference, 2018High-voltage circuit breaker is one of the most critical equipment in power system, and the operating mechanism fault is the main fault state of circuit breaker.
Tong Li +4 more
semanticscholar +1 more source
High-Voltage Vacuum Circuit Breaker a Feasibility Study
2006 International Symposium on Discharges and Electrical Insulation in Vacuum, 2006This study focuses on a compact Vacuum Circuit Breaker for nominal voltage of 72.5 kV, nominal current of 2000 A and short circuit current of 31.5 kA. The dielectric conception of the vacuum interrupter (VI) is based on: - Standard dielectric criteria including the "area effect".
Hans Schellekens, Georges Gaudart
openaire +1 more source
Insulative condition monitoring of high voltage circuit breaker
2010 5th IEEE Conference on Industrial Electronics and Applications, 2010In order to improve power system reliability, high voltage circuit breaker(HVCB) as an important power equipment, the insulation state must be monitored reliably. In the paper, a design approach for real-time data acquisition and remote transmission system base on field programmable gate arrays(FPGA) and ARM technology is presented. The approach adopts
null Li Muyi +2 more
openaire +1 more source
Chromatic Assessment of High-Voltage Circuit Breaker Gases
2020Switching electric currents in high-voltage circuits involves mechanically separating two contacts to form an electric arc plasma which is then quenched. This operation is conducted in a tank containing a vacuum or one type of gas which has good arc-quenching properties.
G. R. Jones +3 more