Results 61 to 70 of about 154,492 (354)

DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application [PDF]

open access: yes, 2015
Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges ...
Aboushady, Ahmed A.   +2 more
core   +2 more sources

Fault diagnosis method for energy storage mechanism of high voltage circuit breaker based on CNN characteristic matrix constructed by sound-vibration signal

open access: yesJournal of Vibroengineering, 2019
Aiming at the problem that some traditional high voltage circuit breaker fault diagnosis methods were over-dependent on subjective experience, the accuracy was not very high and the generalization ability was poor, a fault diagnosis method for energy ...
Shutao Zhao, Erxu Wang, J. Hao
semanticscholar   +1 more source

Cu‐Based MOF/TiO2 Composite Nanomaterials for Photocatalytic Hydrogen Generation and the Role of Copper

open access: yesAdvanced Functional Materials, EarlyView.
HKUST‐1/TiO2 composite materials show a very high photocatalytic hydrogen evolution rate which increases as a function of the irradiation time until reaching a plateau and even surpasses the performance of the 1%Pt/TiO2 material after three photocatalytic cycles.
Alisha Khan   +9 more
wiley   +1 more source

PENGEMBANGAN MEDIA OBYEK 3D VACUUM CIRCUIT BREAKER MEMANFAATKAN PIRAMIDA HOLOGRAM

open access: yesJurnal Kajian Teknologi Pendidikan, 2019
Media obyek 3 dimensi digital vacuum circuit breaker memanfaatkan pirmida hologram adalah media yang menampilkan obyek tiruan yaitu vacuum circuit breaker berbentuk digital grafis memanfaatkan piramida hologram.Tujuan penelitian ini untuk menghasilkan ...
Dana Kurniawan   +2 more
doaj   +1 more source

Arc Phenomena in low-voltage current limiting circuit breakers [PDF]

open access: yes, 2010
Circuit breakers are an important safety feature in most electrical circuits, and they act to prevent excessive currents caused by short circuits, for example. Low-voltage current limiting circuit breakers are activated by a trip solenoid when a critical
Budd, Chris   +4 more
core  

Lipid Nanoparticles for the Delivery of CRISPR/Cas9 Machinery to Enable Site‐Specific Integration of CFTR and Mutation‐Agnostic Disease Rescue

open access: yesAdvanced Functional Materials, EarlyView.
Lipid nanoparticles (LNPs) are optimized to co‐deliver Cas9‐encoding messenger RNA (mRNA), a single guide RNA (sgRNA) targeting the endogenous cystic fibrosis transmembrane conductance regulator (CFTR) gene, and homologous linear double‐stranded donor DNA (ldsDNA) templates encoding CFTR.
Ruth A. Foley   +12 more
wiley   +1 more source

Digital testing of high-voltage circuit breakers

open access: yesIEEE Computer Applications in Power, 2000
The functionality of high-voltage circuit breakers is tested in high-power laboratories. Due to the necessary power and the physical size of the equipment, testing is rather expensive and time consuming. The steps followed so far by the authors in order to enable the digital testing of HV circuit breakers are described in this paper.
Schavemaker, P.H. (author)   +3 more
openaire   +4 more sources

Development of diagnostic and prognostic algorithms for SF6 puffer circuit breakers from transient waveforms: a validation proposal [PDF]

open access: yes, 2009
- This paper presents a validation proposal for development of diagnostic and prognostic algorithms for SF6 puffer circuit-breakers reproduced from actual site waveforms.
Kam, Shui-cheong, Ledwich, Gerard
core   +1 more source

Atomic Size Misfit for Electrocatalytic Small Molecule Activation

open access: yesAdvanced Functional Materials, EarlyView.
This review explores the application and mechanisms of atomic size misfit in catalysis for small molecule activation, focusing on how structural defects and electronic properties can effectively lower the energy barriers of chemical bonds in molecules like H2O, CO2, and N2.
Ping Hong   +3 more
wiley   +1 more source

Research of Fault Diagnosis Method for High-voltage Circuit Breaker Based on Data Fusio

open access: yesGong-kuang zidonghua, 2010
In order to improve fault diagnosis level of high-voltage circuit breaker, the method of using D-S evidence theory to fuse data obtained by different types of sensors was researched and it was used in fault diagnosis for high-voltage circuit breaker ...
MIAO Hong-xia, WANG Hong-hua
doaj  

Home - About - Disclaimer - Privacy