Results 81 to 90 of about 15,918 (222)
Modular multilevel converter with modified half-bridge submodule and arm filter for dc transmission systems with DC fault blocking capability [PDF]
Although a modular multilevel converter (MMC) is universally accepted as a suitable converter topology for the high voltage dc transmission systems, its dc fault ride performance requires substantial improvement in order to be used in critical ...
Abdelsalam, Ibrahim A. +3 more
core +2 more sources
ABSTRACT Converter transformer vibration failures, primarily because of winding and core vibrations, severely impact the safe operation of high voltage direct current (HVDC) systems. These vibrations are influenced by voltage and current, and are transmitted through transformer oil and structural components to the tank. Current numerical models fail to
Peiyu Jiang, Fanghui Yin, Liming Wang
wiley +1 more source
A hybrid high-voltage direct current (HVDC) system comprises a line commutated converter (LCC) at the rectifier side and a voltage source converter (VSC) at the inverter side, combining advantages of both LCC and VSC systems.
Yanting Wang +3 more
doaj +1 more source
Analyses and comparisons of generic models and a novel modeling method of line-commutated converter (LCC)-based high voltage direct current (HVDC) systems are presented for the power system simulator for engineering (PSS/E) simulation tool.
Dohoon Kwon, Youngjin Kim
doaj +1 more source
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
ABSTRACT Damage degradation of epoxy resin insulating materials by free radicals triggered by the ultraviolet irradiation environment at high altitude has become a key issue that restricts the reliability of the bridge arm reactor at high altitude.
Liang Zou +5 more
wiley +1 more source
Ancillary Services in Hybrid AC/DC Low Voltage Distribution Networks [PDF]
In the last decade, distribution systems are experiencing a drastic transformation with the advent of new technologies. In fact, distribution networks are no longer passive systems, considering the current integration rates of new agents such as ...
Barragán Villarejo, Manuel +4 more
core +1 more source
Deterioration Law of Mechanical Properties of Insulation Pressboard Under Multifield Coupled Ageing
ABSTRACT Converter transformers can experience progressive deterioration of their oil–pressboard insulation under elevated temperature, combined AC–DC electrical stress and persistent mechanical vibration. This study investigates how mechanical vibration affects the mechanical properties of insulation pressboard and clarifies the associated microscopic
Jiayi Chen +5 more
wiley +1 more source
Frequency regulation participation of offshore wind farm integrated by diode-rectifer HVDC system
Large-scale wind farms integrated with multi-terminal direct current (MTDC) system decouples the frequency between the wind farms and the receiving end, resulting in weakened frequency regulation ability of the onshore AC grid. Recently a new topology is
Lijun Xie +6 more
doaj +1 more source
Fault mode operation strategies for dual H-bridge current flow controller in meshed HVDC grid [PDF]
Peer ...
Carvalho, Adriano +5 more
core +2 more sources

