Results 1 to 10 of about 17,725 (227)

Application of a new sternoclavicular hook plate in bipolar clavicle injuries [PDF]

open access: yesFrontiers in Surgery, 2023
ObjectiveTo evaluate the safety and effectiveness of using a new sternoclavicular hook plate combined with a shoulder locking hook plate for the treatment of bipolar clavicle injuries.MethodsRetrospective analysis of 7 patients with bipolar clavicle ...
Han Zhang   +3 more
doaj   +4 more sources

Locking Plate with Cerclage Wiring Versus Hook Plate Fixation for Unstable Distal Clavicle Fractures: Is There Still a Role for Hook Plates? [PDF]

open access: yesMedicina
Background and Objectives: Hook plate fixation has been widely used for unstable distal clavicle fractures, but concerns remain regarding implant-related complications and the need for secondary removal. Locking plate fixation with supplementary cerclage
Hyun Seok Song, Hyungsuk Kim
doaj   +5 more sources

Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures [PDF]

open access: yesJournal of Orthopaedic Surgery and Research, 2022
Background Distal clavicular fracture is a shoulder joint injury that is common in clinical settings and is generally surgically treated using the clavicular hook plate technique with a confirmed curative effect.
Dashuang Li   +5 more
doaj   +2 more sources

Optimizing clavicle hook plate fixation through biomechanical analysis of pre-bent plate condition and screw configurations [PDF]

open access: yesFrontiers in Medicine
ObjectiveClavicle hook plates are widely used for internal fixation of clavicle fractures, yet little biomechanical evidence exists to guide optimal plate contouring, screw selection, and screw-hole management. This study aimed to systematically evaluate
Pengfei Nie   +33 more
doaj   +2 more sources

Hook Plate Technique for Bony Mallet Thumb [PDF]

open access: yesCase Reports in Orthopedics, 2019
Bony mallet is a common sport injury, but bony mallet thumb is rarely encountered. We performed open reduction and fixation of bony mallet thumb using a hook plate procedure on a 27-year-old man under general anesthesia. The patient began working one day
Fumihiro Mukasa   +3 more
doaj   +4 more sources

Fifteen-degree clavicular hook plate achieves better clinical outcomes in the treatment of acromioclavicular joint dislocation

open access: yesJournal of International Medical Research, 2018
Objective Clavicular hook plate application is one of the most commonly used treatment methods for acromioclavicular (AC) joint dislocation, although it may cause multiple postoperative complications.
Guanghui Li   +7 more
doaj   +2 more sources

What is the optimal implant removal timing following hook plate fixation in distal clavicle fractures: a retrospective analysis from subacromial osteolysis cases [PDF]

open access: yesBMC Musculoskeletal Disorders
Background Clavicular hook plates are widely used for the fixation of distal clavicle fractures, yet prolonged retention of the hook plate is associated with subacromial osteolysis (SAO), a common complication that may lead to poor functional outcomes ...
Hao-yuan Feng   +6 more
doaj   +2 more sources

Comparative analysis of vertical double plate versus clavicle hook plate for unstable distal clavicle fractures [PDF]

open access: yesScientific Reports
To compare the clinical efficacy of vertical double-plate fixation (combining a distal clavicle locking plate and a radial lateral plate) versus clavicular hook plate fixation for unstable distal clavicle fractures. A retrospective analysis was conducted
Songlin Li   +5 more
doaj   +2 more sources

Observational case series on the clinical performance of the Variable Angle Clavicle Plate and Clavicle Hook Plate 2.7 systems: a study protocol [PDF]

open access: yesFrontiers in Surgery
BackgroundReoperation rates in clavicular fractures and acromioclavicular (AC) joint dislocations are high, often indicated for plate removal due to plate prominence and poor cosmesis. The recently designed 2.7 mm variable angle locking compression plate
Martin Jaeger   +8 more
doaj   +2 more sources

Finite element analysis of internal fixation with clavicular hook plate vs. adjustable loop plate for Neer Type IIB distal clavicle fractures [PDF]

open access: yesFrontiers in Surgery
ObjectiveTo compare the biomechanical stability of clavicular hook plates vs. adjustable strap plates in treating Neer Type IIB distal clavicle fractures, providing evidence for clinical procedure selection.MethodsBased on CT data from a healthy ...
Liwen Zheng, Baopeng Li, Xi Wang
doaj   +2 more sources

Home - About - Disclaimer - Privacy