Results 11 to 20 of about 13,347 (152)
Dual-Energy Computed Tomography (DECT) for Diagnosing Contrast-Induced Encephalopathy (CIE) Mimicking Intracranial Hemorrhage (ICH): A Rare Case [PDF]
Contrast-induced encephalopathy (CIE) is a rare complication after percutaneous coronary intervention (PCI) that mimics intracranial hemorrhage (ICH). Its computed tomography (CT) findings (cortical contrast enhancement, sulci effacement) overlap with ...
Yuhong Shen, Tianhe Ye
doaj +2 more sources
SIFT-GVF-based lung edge correction method for correcting the lung region in CT images
Juxtapleural nodules were excluded from the segmented lung region in the Hounsfield unit threshold-based segmentation method. To re-include those regions in the lung region, a new approach was presented using scale-invariant feature transform and ...
Xin Li +4 more
doaj +2 more sources
Hemorrhage Evaluation and Detector System for Underserved Populations: HEADS-UP
Objective: To create a rapid, cloud-based, and deployable machine learning (ML) method named hemorrhage evaluation and detector system for underserved populations, potentially across the Mayo Clinic enterprise, then expand to involve underserved areas ...
Saif Salman, MD +8 more
doaj +1 more source
Optimization technique for increasing resolution in computed tomography imaging
Starting from the importance of conforming to biological reality in medicine, in this paper we propose an optimization technique for increasing resolution of computed tomography (CT) images acquired using various existing scanners.
I.V. Grossu +3 more
doaj +1 more source
In computed tomography (CT) materials with high-atomic number Z cause image artefacts, thus, errors in CT numbers given in Hounsfield Units (HU). Also, the conventional HU scale (CHU) implemented in CT scanners is truncated, i.e., it does not cover high ...
Ese Zehra, Erni Daniel, Zylka Waldemar
doaj +1 more source
Background It has been suggested that selection of a first‐line endovascular thrombectomy device, that is, contact aspiration (CA) or stent retriever (SR) thrombectomy, could be based on thrombus type.
Nikki Boodt +13 more
doaj +1 more source
Extension of the Stoichiometric Calibration of CT Hounsfield values to Metallic Materials
Nowadays, patients with metallic implants undergoing radiotherapy may suffer from inaccuracy in the treatment plan caused by the implant. To ensure a precise plan an accurate relation between Hounsfield values of the computer tomographic (CT) images and ...
Ese Zehra, Zylka Waldemar
doaj +1 more source
Reduction of Peristalsis-Related Streak Artifacts on the Liver with Dual-Layer Spectral CT
Background: Peristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy. Purpose: To assess dual-layer spectral-detector computed tomography (CT) image reconstructions for reducing intestinal peristalsis-related ...
Sergio Grosu +5 more
doaj +1 more source
Background The purpose of the present study was to describe the CT imaging findings of normal incisive canals and incisive canal cysts and propose cut-off values to differentiate between them.
Naruhiko Ueda +9 more
doaj +1 more source

