Results 81 to 90 of about 2,215,491 (268)
This study compares two techniques for creating lead shielding masks to replace the current process for superficial/orthovoltage facial radiotherapy: Plaster Cast Positive Mould (PCPM), CT Scanned 3D Print (CT3DP), and Optical Scan 3D Print (OS3DP). CT3DP was found to be more accurate and preferred over OS3DP.
Rory Hartley +6 more
wiley +1 more source
Determining the appropriate volume of iodinated contrast media (ICM) for portal venous phase abdominal CT is challenging. Objective image quality assessment demonstrates weight‐based volume dosing reduces the dependence of enhancement on patient size, compared to fixed volume.
Deborah Carrick +6 more
wiley +1 more source
Patient Centring in CT: An International Survey of Clinical Practice and Future Directions
An international survey of 321 radiographers from 43 countries found vertical mis‐centring below the CT isocentre is the most frequent positioning error. Only 34% had access to automated centring systems and 17% used them consistently. Substantial knowledge gaps exist regarding radiation dose and CT number variability, highlighting the need for ...
Yasser H. Hadi +9 more
wiley +1 more source
ABSTRACT This study retrospectively analyzed 92 patients who underwent negative‐pressure suction sheath‐assisted flexible ureteroscopic lithotripsy (observation group) and 85 patients who underwent conventional flexible ureteroscopic lithotripsy (control group).
Ren‐Hui Qiu +4 more
wiley +1 more source
Pleural lipomatosis: A new pose of occult pleura effusion
Intrathoracic benign neoplasm can develop from any tissue; inside the thoracic cavity, however, infrequently, pleural lipomas can be detected, attributable to unusual adipose tissue in the pleural and subpleural layer.
Ahmed M. Abumossalam
doaj +1 more source
Abstract Protein‐energy malnutrition is a common complication in Crohn's disease (CD). In addition to weight loss, patients may develop significant alterations in body composition, including skeletal muscle depletion, which can negatively affect clinical outcomes and quality of life.
Beatriz Gabriela da Costa +10 more
wiley +1 more source
Can the Hounsfield unit predict the success of medically expulsive therapy
Background: We investigate the predictability of medical expulsive therapy (MET) success with alpha blockers based on Hounsfield unit (HU) values and Hounsfield density (HD) values measured by computed tomography (CT) for distal ureteral stones.Methods: Between July 2011 and May 2012, 44 patients (19 female and 25 male) with 5- to 10-mm stones in the ...
Sakip, Erturhan +5 more
openaire +3 more sources
Sarcopenia is common in patients with cirrhosis and contributes to poor prognosis. This study investigated whether transjugular intrahepatic portosystemic shunt (TIPS) is associated with improvement in skeletal muscle mass and whether such improvement translates into better transplant‐free survival in patients with cirrhosis and low skeletal muscle ...
Qinnian Li +5 more
wiley +1 more source
Purpose: The purpose of this study is to test the linearity of the CT system and ascertain the relationship between Hounsfield Unit ( ) values and weight/weight concentrations of iodine ( ) in mixtures.
Anahita Jafari +6 more
doaj +1 more source
Overview of the experimental workflow and main findings of the study investigating Pt‐NPs‐mediated radioenhancement under conventional 134 dose‐rate (CONV) and ultrahigh dose‐rate (UHDR) 9 MeV electron irradiation. Pt‐NP distribution and uptake were characterized in 4T1 spheroids and syngeneic tumor models.
Cathyanne Schott +14 more
wiley +1 more source

