Results 161 to 170 of about 2,754,124 (316)
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan+3 more
wiley +1 more source
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut+2 more
wiley +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal+9 more
wiley +1 more source
The House of Representatives Needs to Expand
In 1929, the United States limited the number of congressional districts for the House of Representatives to 435 seats through the Permanent Apportionment Act. At the time, the average number of people within a congressional district stood at around 280,000 persons. In the 2020 census, this number has risen to 761,000 people per district.
openaire +2 more sources
Dose rate correction of a diode array for universal wedge field dosimetric verification
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen+6 more
wiley +1 more source
Abstract Purpose The Bravos v1.2 control software introduces a ring applicator component type (ACT) with channel length verification to address geometric characteristics and dosimetric discrepancies caused by source positioning inaccuracies. This study aims to commission the ring applicator and investigate the new ring ACT in Bravos 1.2.
Xiuxiu He+4 more
wiley +1 more source
The Role of Cardiovascular Disease Journals in Reporting Sex and Gender in Research. [PDF]
Bairey Merz CN+7 more
europepmc +1 more source