Performance of HPGe Detectors in High Magnetic Fields [PDF]

open access: yesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
A new generation of high-resolution hypernuclear gamma$-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA, the antiproton proton ...
A. Feliciello   +41 more
core   +3 more sources

Optimization of FLUKA detector model for HPGe array

open access: yesRadiation Protection and Environment, 2022
Monte Carlo codes, such as FLUKA, are widely used to optimize calibration of spectrometric systems. HPGe detector array (HDA) for lung monitoring was modeled in FLUKA code using available information about their geometry and optimized for efficiency ...
C S Charubala   +3 more
doaj   +2 more sources

In-situ γ-ray analysis of ground surface radioactivity using portable HPGe γ spectrometer

open access: yesScientific Reports, 2022
As essential high-end equipment for nuclear emergency monitoring, the portable HPGe γ spectrometer currently lacks supporting in-situ measurement methods, limiting its role and value in emergency missions.
Zeqian Wu   +4 more
doaj   +2 more sources

Performance analysis and dead layer profiling of a carbon-fiber encapsulated p-type HPGe detector. [PDF]

open access: yesSci Rep
Accurate geometry-dependent efficiency calibration of High-Purity Germanium (HPGe) detectors is critical for the applications in low radiation level $$\gamma$$ -spectrometry, rare decay studies, and assessments of environmental radioactivity.
Devi S, Tiwari K, Kaintura SS, Singh PP.
europepmc   +2 more sources

Monte Carlo simulation of HPGe gamma-spectrometry systems [PDF]

open access: yesThe Journal of Engineering, 2019
In order to obtain the relationship between energy and channel, the suitable radionuclides are chosen to calibrate. The result shows a goodness of fitting.
Dongjie Hou   +4 more
doaj   +2 more sources

A novel HPGe-BGO pair spectrometer

open access: yesEPJ Techniques and Instrumentation
We report on a novel design for a HPGe-BGO pair spectrometer with the aim to enhance the performance of existing HPGe detectors for high-energy γ-rays. In addition, the BGO shield as a standalone detector allows for a use with the selective detection of ...
Ilja Homm   +16 more
doaj   +2 more sources

Developing a remote gamma-ray spectra collection system (RGSCS) by coupling a high purity Germanium (HPGe) detector with a cosmicguard background reduction device. [PDF]

open access: yesHardwareX
Despite being widely used for high-resolution spectral analysis and quantifying low activity in natural samples, the operations and data analysis of High Purity Germanium (HPGe) gamma-ray detectors are seldom fully automated due to the excessive costs ...
Sun Z, Divakar Nangeelil K, Searcy H.
europepmc   +2 more sources

Development of a low-background HPGe detector at Kamioka Observatory [PDF]

open access: yesProgress of Theoretical and Experimental Physics, 2023
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the first HPGe ...
K. Ichimura   +11 more
semanticscholar   +1 more source

Sediment Radioactivity Levels of Deep-Water Fishery Grounds in Antalya Bay

open access: yesAquatic Sciences and Engineering, 2021
To evaluate the radiological load of the fisheries ground sediments of deep-water areas in the Antalya Bay, 226Ra, 232Th, 40K and 137Cs activity concentration levels were measured with the Gamma Spectroscopy technique using a HighResolution Germanium ...
Süleyman Fatih Özmen, Olgaç Güven
doaj   +1 more source

Efficiency stability of HPGe detectors under distinct count rates

open access: yesBrazilian Journal of Radiation Sciences, 2021
In this work the reproducibility of the efficiency of different HPGe detectors was analyzed under a series of different conditions. The detectors studied were plugged either to a regular analogical amplifier or to a digital signal processing (DSP) device,
Guilherme Soares Zahn   +1 more
doaj   +1 more source