Performance analysis and dead layer profiling of a carbon-fiber encapsulated p-type HPGe detector [PDF]
Accurate geometry-dependent efficiency calibration of High-Purity Germanium (HPGe) detectors is critical for the applications in low radiation level $$\gamma$$ -spectrometry, rare decay studies, and assessments of environmental radioactivity.
Soni Devi +3 more
doaj +2 more sources
Monte Carlo simulation of HPGe gamma-spectrometry systems [PDF]
In order to obtain the relationship between energy and channel, the suitable radionuclides are chosen to calibrate. The result shows a goodness of fitting.
Dongjie Hou +4 more
doaj +2 more sources
A novel HPGe-BGO pair spectrometer
We report on a novel design for a HPGe-BGO pair spectrometer with the aim to enhance the performance of existing HPGe detectors for high-energy γ-rays. In addition, the BGO shield as a standalone detector allows for a use with the selective detection of ...
Ilja Homm +16 more
doaj +2 more sources
Developing a remote gamma-ray spectra collection system (RGSCS) by coupling a high purity Germanium (HPGe) detector with a cosmicguard background reduction device [PDF]
Despite being widely used for high-resolution spectral analysis and quantifying low activity in natural samples, the operations and data analysis of High Purity Germanium (HPGe) gamma-ray detectors are seldom fully automated due to the excessive costs ...
Zaijing Sun +2 more
doaj +2 more sources
Sediment Radioactivity Levels of Deep-Water Fishery Grounds in Antalya Bay
To evaluate the radiological load of the fisheries ground sediments of deep-water areas in the Antalya Bay, 226Ra, 232Th, 40K and 137Cs activity concentration levels were measured with the Gamma Spectroscopy technique using a HighResolution Germanium ...
Süleyman Fatih Özmen, Olgaç Güven
doaj +1 more source
Efficiency stability of HPGe detectors under distinct count rates
In this work the reproducibility of the efficiency of different HPGe detectors was analyzed under a series of different conditions. The detectors studied were plugged either to a regular analogical amplifier or to a digital signal processing (DSP) device,
Guilherme Soares Zahn +1 more
doaj +1 more source
Development of an environmental monitoring station for HPGe detectors
Neutron Activation Analysis (NAA) is a well-established nondestructive analytic technique where the gamma radiation emitted by an irradiated sample is analyzed using an HPGe detector.
Gleiser Rodrigues de Melo +3 more
doaj +1 more source
A new technique for quick identification of defective region inside γ-ray detector [PDF]
The γ-ray detection efficiency of a detector decreases over time due to factors like radiation damage or an increase in the thickness of the inactive dead layer.
Das Biswajit +7 more
doaj +1 more source
Calibration of HPGe–HPGe coincidence spectrometer through performing standardisation of 125I activity by X-ray-gamma coincidence spectrometry using two HPGe detectors [PDF]
Abstract An X-ray-gamma coincidence measurement method for efficiency calibration of a HPGe–HPGe system, using the methodology for activity standardisation of 125 I, has been developed. By taking one list-mode time-stamped measurement of the 125 I source, six spectra were generated in post-processing: total spectra, coincidence spectra and energy ...
Marković, Nikola +4 more
openaire +2 more sources
Emergency unmanned airborne spectrometric (HPGe) monitoring system
After a nuclear or radiation event, emergency responders and radiation protection authorities need quick and credible information based on reliable accident and post-accident radiological data. However, risks to people in the vicinity of the source pose serious measurement challenges.
Jan Rusňák +5 more
openaire +2 more sources