Direct-reaction studies by particle-γ coincidence spectroscopy using Csi-Hpge and Si-Hpge arrays
AIP Conference Proceedings, 2013Particle-γ and particle-γ-γ coincidence spectroscopy has several advantages in the study of direct reactions (particularly in inverse kinematics) since it can generally allow determination of: decay paths; high-precision level energies; multipolarities of transitions; and cross sections.
openaire +1 more source
Development of a rugged HPGe detector
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1986Abstract A rugged HPGe detector capable of taking high resolution data in a vibrational environment has been developed. The objectives included a detector with 35% gamma efficiency and 1.90 keV energy resolution (both quantities measured at 1332.5 keV), a dewar with a capacity of 1.2 l and a hold time of 24 h.
Louis A. Beach, Gary W. Phillips
openaire +1 more source
Design of a radiation shield for an HPGe detector for a reactor-based PGNAA facility
Radiation Physics and Chemistry, 2023Z. Ghasemi +3 more
semanticscholar +1 more source
Modelling orthogonal strip HPGe detector systems
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007Abstract The development of orthogonal planar strip high purity germanium (HPGe) detectors offers the advantages of good energy and three dimensional spatial resolution of photon interactions. The use of such devices for Positron emission Tomography (PET) are being investigated by the SmartPET collaboration.
Paul R. Smith +7 more
openaire +1 more source
HPGe virtual point detector for radioactive disk sources
Applied Radiation and Isotopes, 2007Validity of the model of a virtual point detector (implying existence of a point where all interactions virtually occur) was confirmed for measurements of radioactive disk sources with HPGe detectors. The existing correlation of the count rates with the distance between the virtual plain detector and the detector face makes it possible to inter- and ...
Z B, Alfassi +3 more
openaire +2 more sources
Detailed optimization procedure of an HPGe detector using Geant4 toolkit
Journal of Radioanalytical and Nuclear Chemistry, 2023M. Travar +8 more
semanticscholar +1 more source
Detection efficiency calibration for an array of fourteen HPGe detectors.
Applied Radiation and Isotopes, 2023S.Y. Park +11 more
semanticscholar +1 more source
Radionuclide Measurement Using HPGe Gamma Spectrometry
2006In this chapter we have outlined the basic methodology, equipment, and software necessary to determine activities of 137Cs and other gamma-emitting radionuclides using HPGe gamma-spectrometry methods. The analysis of radioactivity in samples at environmental levels is a complex task.
P. J. Wallbrink, D. E. Walling, Q. He
openaire +1 more source
Calculation of the volume of an HPGe crystal
Radiation Protection Dosimetry, 2011An important characteristic of a high-purity germanium detector for gamma spectrometry is the volume of the crystal, which relates to the detection efficiency and to the measured background level. The crystal dimensions provided by the detector manufacturer were used to calculate the crystal volume.
Y, Nir-El, D, Har-Even
openaire +2 more sources