‘Universal’ representation of HPGe detector efficiencies

Radiation Measurements, 2016
Abstract By fitting a simple 4-parameter function to twelve sets of HPGe detector efficiency measurements, an approximate ‘universal’ expression good to ±15% is obtained for HPGe absolute full-energy-peak efficiencies as a function of photon energy between ∼125 and ∼1750 keV for a ∼4-to-1 range of crystal volumes and for coaxial and planar crystal ...
openaire   +1 more source

Precise modeling of a coaxial HPGe detector

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
Abstract Measured spatial dependence of the full energy peak efficiency for point sources in the region of photon energies from 60 to 1115 keV was analyzed using the GEANT system. A systematic iteration procedure was developed for the fine geometric modeling of the HPGe detector structure.
S. Ashrafi, A. Likar, T. Vidmar
openaire   +1 more source

Optimization of Electrically Cooled Complex HPGe Detector

2012 Sixth UKSim/AMSS European Symposium on Computer Modeling and Simulation, 2012
This article presents a novel technique used for design and optimization of a composite HPGe detector with two or three encapsulated Ge-crystals and based on electromechanical cooling engine. In this technique is accentuated on the detailed investigation of the heat transfer processes -- each one separately and in complex, and their impact on the ...
Ivan Kojouharov   +4 more
openaire   +1 more source

The simulation studies of PC-HPGe detector

2011 IEEE Nuclear Science Symposium Conference Record, 2011
Having the merits of low capacitance and low energy threshold, PC-HPGe (Point-Contact High Purity Germanium) detector has been proposed for the direct WIMP (Weakly Interacting Massive Particle) searches in CDEX (China Dark matter Experiment), which is located in CJPL (China Jing Ping underground Laboratory) with a rock overburden of about 2400 m ...
Zifeng Lv   +5 more
openaire   +1 more source

The virtual point detector concept for HPGe planar and semi-planar detectors

Applied Radiation and Isotopes, 2006
The virtual point detector assumption was validated for planar and semi-planar detectors. The distance of the virtual point detector from the detector face is larger than the thickness of the detector, which means that the virtual detector position is outside the volume of the detector.
Z B, Alfassi, O, Pelled, U, German
openaire   +2 more sources

Analysis of HPGe-detector relative photopeak efficiency

Il Nuovo Cimento A, 1995
The dependence of the HPGe-detector efficiency on its intrinsic and geometrical properties such as energy resolution, electronic noise, charge production statistics and effect of the rise time is considered. This study also includes the detector's sensitive volume.
openaire   +1 more source

HPGe Detector Efficiency Calibration Using HEU Standards

2000
The Analytical Development Section of SRTC was requested by the Facilities Disposition Division (FDD) to determine the holdup of enriched uranium in the 321-M facility as part of an overall deactivation project of the facility. The 321-M facility was used to fabricate enriched uranium fuel assemblies, lithium-aluminum target tubes, neptunium assemblies,
openaire   +1 more source

A Multi-Point Contact HPGe Detector

IEEE Transactions on Nuclear Science, 2014
Michael P. Dion   +7 more
openaire   +1 more source

FADC electronics design for HPGe detector

2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC), 2013
openaire   +1 more source