Results 11 to 20 of about 1,794 (181)

Investigation of inter-source and intra-source spectral variations in an electronic brachytherapy source using spectral measurements and Monte Carlo simulations. [PDF]

open access: yesMed Phys
Abstract Background The Xoft electronic brachytherapy source is commonly used to treat superficial lesions and tumors located at shallow depths. However, uncertainties in material composition and geometry, mainly arising due to the manual assembly of the x‐ray tube components, contribute to inter‐source variability in the tube output spectrum.
Esmaelbeigi A   +6 more
europepmc   +2 more sources

Gamma-spectrometric module based on HPGe detector for radiation portal monitors [PDF]

open access: yesNuclear Technology and Radiation Protection, 2015
The appearance of small-sized and powerful enough electric cryocoolers of various types on the market, has opened the perspective of HPGe detectors application, cooled by such coolers, in radiation portal monitors.
Kondratjev Vladimir   +2 more
doaj   +1 more source

Electronics Package for Rugged HPGE Detectors [PDF]

open access: yesIEEE Transactions on Nuclear Science, 1986
A prototype electronics package of amplifier, ADC, pulser, data-bus interface, bias supply and low voltage supply has been developed to process high resolution data from rugged intrinsic germanium detectors with high reliability in a harsh environment.
L. A. Beach, G. W. Phillips
openaire   +1 more source

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

open access: yesNuclear Engineering and Technology, 2023
This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special ...
Marcel Ohera   +4 more
doaj   +1 more source

Effects of magnetic fields on HPGe tracking detectors [PDF]

open access: yesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
We present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers.
I.Y. Lee, A.O. Macchiavelli
openaire   +4 more sources

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors [PDF]

open access: yesThe European Physical Journal C, 2022
AbstractP-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p$
Arnquist, IJ   +64 more
openaire   +7 more sources

Optimization of FLUKA detector model for HPGe array

open access: yesRadiation Protection and Environment, 2022
Monte Carlo codes, such as FLUKA, are widely used to optimize calibration of spectrometric systems. HPGe detector array (HDA) for lung monitoring was modeled in FLUKA code using available information about their geometry and optimized for efficiency ...
C S Charubala   +3 more
doaj   +1 more source

Calibration of spectrometric detectors for air kerma rates in environmental monitoring [PDF]

open access: yesNuclear Technology and Radiation Protection, 2020
The spectrometric systems, especially based on NaI(Tl) and HPGe detectors, are used for nuclide identification and calculation of their activities from the ground measurements and air-borne monitoring.
Ohera Marcel, Sas Daniel, Sladek Petr
doaj   +1 more source

Testing and modeling HpGe detector with anti-Compton shield

open access: yesEurasian Journal of Physics and Functional Materials, 2021
Simulating with GEANT4 of anti-Compton shield containing eight BGO scintillators that works on anti-coincidence with HpGe detector was presented.
N. T. Tursunbayev, B. A. Urazbekov
doaj   +1 more source

A 235U mass measurement method for UO2 rod assembly based on the n/γ joint measurement system

open access: yesNuclear Engineering and Technology, 2020
Fast-Neutron Multiplicity Counter based on Liquid Scintillator Detector can directly measure the fast neutron multiplicity emitted by UO2 rod. HPGe gamma spectrometer; which has superior energy resolution; is routinely used for the gamma energy spectrum ...
Jianqing Yang   +8 more
doaj   +1 more source