Results 21 to 30 of about 1,794 (181)

The SPICE Detector at ISAC

open access: yesEPJ Web of Conferences, 2013
A new ancillary detector system for the TIGRESS HPGe array called SPectrometer for Internal Conversion Electrons (SPICE) is currently under development. SPICE consists of a segmented electron detector, photon shield and a permanent magnetic lens.
Garnsworthy A.B.   +9 more
doaj   +1 more source

Bayesian algorithm to estimate position and activity of an orphan gamma source utilizing multiple detectors in a mobile gamma spectrometry system.

open access: yesPLoS ONE, 2021
To avoid harm to the public and the environment, lost ionizing radiation sources must be found and brought back under the regulatory control as soon as possible. Usually, mobile gamma spectrometry systems are used in such search missions.
Antanas Bukartas   +3 more
doaj   +1 more source

Assessment of the inactive dead layer thickness of old high-purity germanium detector: A study by Monte Carlo simulations and experimental verification

open access: yesRadiation Protection and Environment, 2017
High-purity germanium (HPGe) detectors are commonly used for high-resolution gamma spectrometry. A HPGe detector considered for this study was in continuous operation for the past 15 years in our laboratory.
Narayani Krishnan   +3 more
doaj   +1 more source

Radon Mitigation Applications at the Laboratorio Subterráneo de Canfranc (LSC)

open access: yesUniverse, 2022
The Laboratorio Subterráneo de Canfranc (LSC) is the Spanish national hub for low radioactivity techniques and the associated scientific and technological applications.
Javier Pérez-Pérez   +18 more
doaj   +1 more source

Ratio of spectral averaged cross sections measured in standard 252Cf(sf) and 235U(nth,f) neutron fields [PDF]

open access: yesEPJ Web of Conferences, 2020
The results of systematic evaluations of spectrum averaged cross section (SACS) measurements in the fission neutron fields of 252Cf and 235U are presented.
Schulc Martin   +5 more
doaj   +1 more source

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II. [PDF]

open access: yesJ Synchrotron Radiat
The development of multimodal X‐ray computed tomography capabilities, including imaging, fluorescence, diffraction, and scattering, at the 28‐ID‐2 beamline of the National Synchrotron Light Source II is described.We report the commissioning of a multimodal computed tomography experimental setup at the 28‐ID‐2 (XPD) beamline of the National Synchrotron ...
Topsakal M   +6 more
europepmc   +2 more sources

True coincidence summing corrections in HPGe detectors

open access: yesHNPS Advances in Nuclear Physics, 2023
The true coincidence effect is studied in two High Purity Germanium (HPGe) detectors for a variety of isotopes, source geometries and source to detector configurations, via computational tools based on Monte–Carlo simulations. Τhe upgraded patch of MCNP code MCNP–CP and the 2018 version of PENELOPE, which take into account the decay scheme of each ...
Anastasia Milioni   +4 more
openaire   +1 more source

Modeling the impact of uncertainty in detector specification on efficiency values of a HPGe detector using ANGLE software [PDF]

open access: yesNuclear Technology and Radiation Protection, 2013
The objective of this study is to model the impact of uncertainties in the engineering specifications of a typical p-type HPGe detector on the efficiency values when the measured soil sample is in contact geometry with the detector.
Miller Maurice, Voutchkov Mitko
doaj   +1 more source

Simulation study of signal readout for multi-electrode high purity germanium detector

open access: yesHe jishu
BackgroundDue to high energy resolution and position sensitivity features, the multi-electrode high purity germanium (M-HPGe) detector is widely applied in rare event physics for events extraction.PurposeThis study aims to make use of pulse shape in M ...
YANG Jingzhe   +7 more
doaj   +1 more source

Uncertainties of calculated coincidence-summing correction factors in gamma-ray spectrometry [PDF]

open access: yesEPJ Web of Conferences, 2020
Uncertainty propagation to the γ-γ coincidence-summing correction factor from the covariances of the nuclear data and detection efficiencies have been formulated.
Semkova V., Otuka N., Plompen A.J.M.
doaj   +1 more source