Simulation study on transient temperature field characteristics of HPGe detectors simulated by the COMSOL method

open access: yesHe jishu
BackgroundHigh-purity Ge (HPGe) detectors are widely used in nuclear science, technology, and national defense because of their excellent energy resolution capability, which enables them to fingerprint gamma rays and accurately determine nuclide types ...
QUE Ziang   +5 more
doaj   +1 more source

Precision measurement of radioactivity in gamma-rays spectrometry using two HPGe detectors (BEGe-6530 and GC0818-7600SL models) comparison techniques: Application to the soil measurement

open access: yesMethodsX, 2017
To obtain high quality of results in gamma spectrometry, it is necessary to select the best HPGe detector for particular measurements, to calibrate energy and efficiency of gamma detector as accurate as possible.
Guembou Shouop Cebastien Joel   +7 more
doaj   +1 more source

Development of portable HPGe spectrometer for in situ measurements [PDF]

open access: yesNuclear Technology and Radiation Protection, 2015
In situ applications require a very high level of portability of high-resolution spectrometric equipment. Usage of HPGe detectors for radioactivity measurements in the environment or for nuclear safeguard applications, to combat illicit ...
Kail Artjoms   +4 more
doaj   +1 more source

Efficiency simulation and coincidence-summing correction for HPGe detector

open access: yesHe jishu
BackgroundIn order to enhance the detection sensitivity of HPGe detectors for measuring the low-level activity of radionuclides, samples are usually measured as close to the detector as possible to improve the detection efficiency, which inevitably leads
ZHANG Ruiqin   +8 more
doaj   +1 more source

Activity Evaluation Methodology for the Disposed Medical Linear Accelerators

open access: yesApplied Sciences, 2022
For the medical linear accelerators (linac) that utilize more than 10 MV of photon energy, components inside the linac head become radioactivate during the 10–15-year operating cycle.
Na Hye Kwon   +6 more
doaj   +1 more source

System noise of a digital pulse processing module for nuclear instrumentation [PDF]

open access: yesEPJ Web of Conferences, 2020
Digital pulse processing finds a widespeed use in nuclear instrumentation. This work presents a digital pulse processing (DPP) module based on an FPGA and a 16-bit 125 MHz ADC and analyses the system noise distribution by acquired digital data using this
Ma Y   +4 more
doaj   +1 more source

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector [PDF]

open access: yesJournal of Astronomy and Space Sciences, 2014
Odyssey, one of the NASA’s Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface.
Meeyoung Jeong   +4 more
doaj   +1 more source

Characterisation of a small electrode HPGe detector [PDF]

open access: yesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
© 2019 Elsevier B.V. Small electrode HPGe detectors in an inverted coaxial geometry are increasingly in use in applications where both high efficiency and excellent energy resolution are required. The unusual electric field configuration of these detectors results in extremely long charge collection times compared to planar and coaxial devices. In this
Unsworth, C   +11 more
openaire   +2 more sources

Photonuclear Population of 229m,gTh in Th‐Doped Crystals Toward Nuclear Clock Development

open access: yesAdvanced Science, EarlyView.
This study demonstrates a novel photonuclear approach for producing the nuclear clock isomer 229mTh in thorium‐doped crystals, overcoming current supply limitations. Through cross‐section calculations and Monte Carlo simulations, we identify optimal crystal materials and irradiation conditions, achieving high signal‐to‐noise ratios.
Hao‐Yang Lan   +9 more
wiley   +1 more source

Study on Calibration Method of γ Spectrometer for BNCT Treatment

open access: yesYuanzineng kexue jishu
Limited by the characteristics of the boron neutron capture therapy (BNCT) treatment beam, it is difficult to measure the γ ray energy spectrum of the source term. There are few relevant work has been carried out.
ZHANG Shufeng1, SHI Bin1, XIAO Hongfei2, CHEN Jun1, LIU Yuntao1, ZHANG Qingxian2, SONG Mingzhe1
doaj   +1 more source