Results 91 to 100 of about 43,824 (199)
Purpose: The aim of this study was to compare the Humphrey MATRIX visual field (frequency doubling technology threshold) and Swedish interactive threshold algorithm (SITA) standard strategy white on white perimetry in detecting glaucomatous visual field
Prema Raju +5 more
doaj
Relationship Between Foveal Cone Structure and Visual Acuity Measured With Adaptive Optics Scanning Laser Ophthalmoscopy in Retinal Degeneration. [PDF]
PurposeTo evaluate foveal function in patients with inherited retinal degenerations (IRD) by measuring visual acuity (VA) after correction of higher-order aberrations.MethodsAdaptive optics scanning laser ophthalmoscopy (AOSLO) was used to image cones in
Duncan, Jacque L +7 more
core
High frequency [1-500 MHz] measurements of the Magneto-Impedance (MI) of glass-covered Co$_{69.4}$Fe$_{3.7}$B$_{15.9}$Si$_{11}$ microwires are carried out with various metal-to-wire diameter ratios.
Fessant, A. +3 more
core +1 more source
Glaucomatous visual fields. FASTPAC versus full threshold strategy of the Humphrey Field Analyzer.
This study examined how FASTPAC, a fast strategy for the Humphrey Field Analyzer (HFA), compares to the standard 4/2-dB full threshold strategy in patients with glaucoma.The author tested one eye each of 50 patients with glaucoma (23 with only relative defects, 27 with at least one absolute defect; age range, 25 to 79 years; median age, 61.5 years ...
M, Schaumberger +2 more
openaire +1 more source
Monthly newsletter providing updates of interest to the Boston University School of Medicine ...
Boston University School of Medicine Office of Informational Services
core
A Spatio-Temporal Bayesian Network Classifier for Understanding Visual Field Deterioration [PDF]
Progressive loss of the field of vision is characteristic of a number of eye diseases such as glaucoma which is a leading cause of irreversible blindness in the world. Recently, there has been an explosion in the amount of data being stored on patients
Garway-Heath, D +3 more
core
Purpose To characterize differences in corneal biomechanics in high (HPG) and normal pressure (NPG) primary open-angle glaucoma, and its association to disease severity.
Lisa Ramm +5 more
doaj
Comparison of the Humphrey Field Analyzer and Photopic Negative Response of Focal Macular Electroretinograms in the Evaluation of the Relationship Between Macula Structure and Function. [PDF]
Hirooka K +3 more
europepmc +1 more source
Index to NASA Tech Briefs, 1975 [PDF]
This index contains abstracts and four indexes--subject, personal author, originating Center, and Tech Brief number--for 1975 Tech ...
core +1 more source
Peripapillary and macular choroidal thickness in glaucoma. [PDF]
PurposeTo compare choroidal thickness (CT) between individuals with and without glaucomatous damage and to explore the association of peripapillary and submacular CT with glaucoma severity using spectral domain optical coherence tomography (SD-OCT ...
Bitrian, Elena +7 more
core +2 more sources

