Results 161 to 170 of about 6,865,634 (210)

Physics‐Informed Generative Machine Learning for Designing Crack‐Free γ′‐Strengthened Ni‐Based Superalloys for Laser Powder Bed Fusion

open access: yesMaterials Genome Engineering Advances, EarlyView.
This research proposes a physics‐informed generative machine learning framework to design SHA800, a crack‐free γ′‐strengthened nickel‐based superalloy for laser powder bed fusion, achieving a 43% γ′ volume fraction and 587 HV0.2 hardness. ABSTRACT Fabricating γ′‐strengthened nickel‐based superalloys via laser powder bed fusion (LPBF) faces significant ...
Kai Guo   +11 more
wiley   +1 more source

Evaluation of Third‐Order Motion‐Compensated Cardiac Diffusion Tensor Imaging Across Cardiac Phases Using an Ultra‐High‐Performance Clinical Scanner

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate a third‐order motion‐compensated spin echo (M3‐MCSE) sequence at multiple cardiac phases on a clinical 3 T MRI scanner with ultra‐high performance (UHP) gradients (200 mT/m), compared with stimulated echo acquisition mode (STEAM) and second‐order MCSE (M2‐MCSE) for cardiac diffusion tensor imaging (cDTI).
Ke Wen   +8 more
wiley   +1 more source

Uncertainty Quantification for Cardiac Diffusion Tensor Imaging Without Additional Datasets

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Cardiac diffusion tensor imaging (cDTI) is subject to physiological noise, thermal noise, and signal corruption, which cause errors in diffusion measures. While a larger dataset can be decimated to investigate the general precision of measures from fitting smaller datasets, uncertainty quantification (UQ) methods for fitting entire ...
Sam Coveney   +7 more
wiley   +1 more source

Serum Albumin Levels Are Associated with Total Brain and Hippocampal Volume but Not with White Matter Lesion Volume in Older Japanese Adults Without Cognitive Decline: A Cross-Sectional Study. [PDF]

open access: yesNutrients
Usui Y   +19 more
europepmc   +1 more source

Reducing Motion Artifact in High Resolution 7 T MRI Using the Magnetic Resonance Minimal Motion (“MR‐MinMo”) Head Stabilization Device

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the effectiveness of the MR‐MinMo head stabilization device in mitigating motion artifacts during long‐duration, high‐resolution 7 T MRI scans, with and without retrospective motion correction Methods The MR‐MinMo was tested on seven pediatric and 12 adult healthy volunteers using 0.6 mm isotropic, 3D Multi‐Echo Gradient ...
Jyoti Mangal   +10 more
wiley   +1 more source

Toward Free‐Breathing Renal CEST MRI: Preclinical Evaluation of a Novel Prospective Respiratory Triggering Approach

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Endogenous renal chemical exchange saturation transfer (CEST) imaging enables contrast‐agent‐free assessment of renal metabolism but is highly sensitive to respiratory motion. Existing approaches, such as timed breathing, require high patient compliance or preclinical mechanical ventilation, limiting clinical translation.
Patrik Jan Gallinnis   +12 more
wiley   +1 more source

The Role of Distal Medial Cuneiform Angle in Hallux Valgus: A Systematic Review. [PDF]

open access: yesCureus
Al Zuabi ZAA   +6 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy