Results 51 to 60 of about 100,450 (224)
The parallel multi-branch pipeline system is usually used for fluid transportation and distribution in the cooling of high-power electronic equipment, especially in radar equipment.
Qipeng Li +7 more
doaj +1 more source
A scalable, color‐adaptive radiative cooling coating is developed to enable dynamic spectral regulation via a reversible thermochromic transition at ~45 °C and a high solar reflectance of 91.7%. The coating achieves 4.44 °C outdoor sub‐ambient cooling while providing robust superhydrophobicity and environmental durability through its micro/nano ...
Ziqi Li +8 more
wiley +1 more source
Analysis of Fouling in HVAC Heat Exchangers by CFD [PDF]
The purpose of this study is to identify parameters influence on the particle deposition within fin and tube heat exchanger of air-conditioning systems by CFD analysis.
Mohammad Reza Jafari Nasr, Aida Balaei
doaj
Coupled TRNSYS-CFD simulations evaluating the performance of PCM plate heat exchangers in an Airport Terminal building displacement conditioning system [PDF]
This is the post-print version of the Article. The official published version can be accessed from the link below. Copyright @ 2013 Elsevier.This paper reports on the energy performance evaluation of a displacement ventilation (DV) system in an airport ...
Alauzet +46 more
core +1 more source
Abstract Brazed plate heat exchanger (BPHE) was analyzed using computational fluid dynamics (CFD) simulations by ANSYS Fluent to investigate the chevron‐patterned plates. The influence of geometric parameters, including corrugation pitch, depth, and angle was analyzed.
J. S. Huang, K. B. Then, X. W. Wang
wiley +1 more source
Evaluation of a novel porous antimicrobial media for industrial and HVAC water biocontrol
A novel treatment method, consisting of pea-gravel with a marine coating supplemented with alkyldimethylbenzylammonium chloride (ADBAC or benzalkonium chloride), has been examined for its antimicrobial performance and coating stability in aqueous ...
William James Blanford +1 more
doaj +1 more source
Satellite (MODIS) mapping links Urban Heat Island (UHI) intensity to city‐scale energy demand—higher daytime cooling demand and altered nighttime heating demand—supporting targeted mitigation and planning. ABSTRACT This study examines the surface urban heat island (SUHI) effect on building energy consumption in Tehran from 1998 to 2024, utilizing MODIS
Rasool Maroofiazar, Ali Maboudi Reveshti
wiley +1 more source
Due to the high cost of peak hour power generation and a push towards sustainability, the need for demand response (DR) is increasing. Compared to commercial-level DR, residential-level DR is more challenging.
Yue Zhang +4 more
doaj +1 more source
Experimental determination of cold water temperature at the inlet to solar water storage tanks [PDF]
In the present work, results of experimental research on the mains water temperature supplying the Solar Domestic Hot Water system in the period from 2016 to 2018 are shown.
Zukowski Miroslaw
doaj +1 more source
ABSTRAK Pada penelitian ini dibahas tentang pembangkit listrik termoelektrik pada refrigerasi air conditioner. Bagian sistem terdiri dari air conditioner yang sudah dimodifikasi dengan menambahkan 50 buah modul termoelektrik dengan kontroler. Penggunaan
AHMAD SETIAWAN +3 more
doaj +1 more source

