A transient and non-unit-based protection technique for DC grids based on the rate-of-change (R-o-C) of the fault induced travelling wave components [PDF]
This paper presents a transient and non-unit-based protection scheme for consideration in DC grids of the future. The technique utilises the rate-of-change (R-o-C) of the associated travelling wave components following the occurrence of a fault to ...
Azizi +24 more
core +1 more source
Fault Location Test for HVDC Submarine Cables [PDF]
AbstractThe simplified fault location method which is described in this paper is tested at HVDC submarine cable test yard located in KEPCO Power Testing Center of Korea. The total length of tested submarine cable is 194 m, and it has 4 earth points, each point is grounded between shield layer and seawater under the sea respectively.
Chae-kyun Jung +4 more
openaire +1 more source
Power cable stresses caused by transmission line faults in next generation VSC-MMC systems
Until today, HVDC systems based on Modular Multilevel Voltage Source Converters (VSC-MMC) have exclusively been realised with cross-linked polyethylene (XLPE) cable transmission in monopolar configuration.
Philipp Tünnerhoff +3 more
doaj +1 more source
Research progress of semiconductive shielding layer of HVDC cable
As an indispensable part of high-voltage direct current (HVDC) cable, the semiconductive shielding layer plays the role of uniforming electric field in the cable.
Yanhui Wei +6 more
doaj +1 more source
Polypropylene-based nanodielectrics for HVDC cables
Due to the limited recyclability and operating temperature of the cross-linked polyethylene (XLPE) insulation for high voltage direct current (HVDC) cables, renewable next-generation insulation materials have drawn great attention during recent years, especially polypropylene-based nanodielectrics. The filler-matrix interphase within nanodielectrics is
openaire +2 more sources
Stability analysis of electric power systems for ‘more electric’ aircraft [PDF]
This paper presents a comprehensive assessment of small-signal stability for a “more-electric” aircraft power system consisting of a synchronous variable-frequency generator which supplies several power electronic controlled loads via an 18-pulse ...
Griffo, Antonio, Howe, D., Wang, J.B.
core
Application of Grey Wolf Optimizer Algorithm for Optimal Power Flow of Two-Terminal HVDC Transmission System [PDF]
This paper applies a relatively new optimization method, the Grey Wolf Optimizer (GWO) algorithm for Optimal Power Flow (OPF) of twoterminal High Voltage Direct Current (HVDC) electrical power system.
Hassan, Heba Ahmed
core +1 more source
Modular multilevel converter losses model for HVdc applications [PDF]
Multi-terminal high voltage dc (HVdc) grids can eventually became a feasible solution to transport energy to remote and/ or distant areas and its exploitation depend, among other things, on the performance of the converter terminals.
Antonio Ferreira, Abel +1 more
core +2 more sources
Development of Cable Accessories with SiR Insulation for 320kV HVDC Cables [PDF]
HVDC cable accessories with environment-friendly insulating material and flexible compatibility other than ethylene propylene diene monomer (EPDM) are demanded in the global market. In this paper, the authors present their newly developed silicone rubber (SiR) insulated cable joints and terminations as a potential answer to that call. Simulation models
Xu, Ruoyu +6 more
openaire +2 more sources
Full Bridge MMC Converter Optimal Design to HVDC Operational Requirements [PDF]
This project is funded by RTE, Paris, FrancePeer ...
Jovcic, Dragan +3 more
core +1 more source