Results 51 to 60 of about 660,190 (184)
A massive number of DC circuit breaker is usually necessary to be installed to protect HVDC grids from DC faults, this will lead to high capital costs because large number of expensive IGBT-in-series are used.
Qingpeng Zeng +9 more
doaj +1 more source
Multi-terminal voltage-sourced converters (VSC) high-voltage direct current (HVDC) transmission system is expected to play a vital role in future power systems.
Bin Chang +6 more
doaj +1 more source
In this study, a LCC-VSC hybrid HVDC transmission system was taken as an example. The valve and neutral overvoltage of the hybrid HVDC system were simulated and then calculated at the VSC converter station by installing a blocking diode and a DC circuit ...
Wang Dongju, Zhou Hao
doaj +1 more source
Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN +4 more
doaj +1 more source
Systematic Approach to HVDC Circuit Breaker Sizing [PDF]
High-voltage direct current (HVDC) grids can be protected by HVDC circuit breakers (DCCB) to selectively clear DC side faults and assure continuous operation of the healthy parts in the grid. Line inductors in series with DCCBs are essential to reduce the rate of rise of the fault current and to slow down the voltage decline in the healthy parts of the
Abedrabbo, Mudar +2 more
openaire +1 more source
Converter for Voltage Source HVDC Links: Current Status and Future Challenges
This article discusses the current state of DC HVDC technology. The article describes the history of DC HVDC technology, starting with its early development as a voltage source, and then discusses the introduction of line-cutting into current designs ...
Atheer Ahmed Kadhim +2 more
doaj +1 more source
4-Pole Hybrid HVDC Circuit Breaker for Pole-to-Pole (PTP) Fault Protection
Numerous problems have emerged with the development of HVDC transmission technology. One of them is the fault current that occurs when there is an issue in the line. In particular, in the case of a PTP (pole-to-pole) fault, a DCCB design suitable for the
Geon Kim +7 more
doaj +1 more source
Research on the Modification Plan of HVDC Transfer Switch Arrester
[Introduction] During the earth return and metallic return mode conversion of China's HVDC transmission projects in operation, several MRTB (metallic return transfer breaker) or ERTB (earth return transfer breaker) oscillation platform arrester damage ...
LU Yuxin +5 more
doaj +1 more source
Integrated HVDC Circuit Breakers With Current Flow Control Capability [PDF]
Two key problems in meshed high-voltage direct current (HVDC) transmission grids are managing line power flows and protection against dc faults. Current flow controllers (CFCs) will be required to balance cable currents in meshed dc grids, in order to prevent individual line power capacity limits restricting overall power flow in the grid.
Cwikowski, Oliver +6 more
openaire +4 more sources
A capacitor-based DC circuit breaker for HVDC power grid
DC circuit breakers (DCCBs) are the critical equipment to isolate faults in high-voltage DC grids. The improvement of interruption performances of capacitor-based DCCBs (C-DCCBs) has been widely researched.
Zhuang Xu +4 more
doaj +1 more source