Results 31 to 40 of about 663,280 (150)

Systematic Approach to HVDC Circuit Breaker Sizing [PDF]

open access: yesIEEE Transactions on Power Delivery, 2020
High-voltage direct current (HVDC) grids can be protected by HVDC circuit breakers (DCCB) to selectively clear DC side faults and assure continuous operation of the healthy parts in the grid. Line inductors in series with DCCBs are essential to reduce the rate of rise of the fault current and to slow down the voltage decline in the healthy parts of the
Abedrabbo, Mudar   +2 more
openaire   +1 more source

Integrated HVDC Circuit Breakers With Current Flow Control Capability [PDF]

open access: yesIEEE Transactions on Power Delivery, 2018
Two key problems in meshed high-voltage direct current (HVDC) transmission grids are managing line power flows and protection against dc faults. Current flow controllers (CFCs) will be required to balance cable currents in meshed dc grids, in order to prevent individual line power capacity limits restricting overall power flow in the grid.
Cwikowski, Oliver   +6 more
openaire   +4 more sources

Mechanism of Damage and Micro‐Characterisation of Irradiation‐Induced Free Radicals on the Epoxy Insulation of the Bridge Arm Reactors at High Altitude

open access: yesHigh Voltage, EarlyView.
ABSTRACT Damage degradation of epoxy resin insulating materials by free radicals triggered by the ultraviolet irradiation environment at high altitude has become a key issue that restricts the reliability of the bridge arm reactor at high altitude.
Liang Zou   +5 more
wiley   +1 more source

Circuit Breaker Failure Protection Strategy for HVDC Grids [PDF]

open access: yes, 2021
HVDC grids demand the fast and reliable operation of the protection system. The failure of any protection element should initialize a backup protection almost immediately in order to assure the system’s stability.
Pérez Molina, María José   +7 more
core   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

Reduced DC circuit breaker requirement on mixed converter HVDC networks [PDF]

open access: yes, 2015
Recently proposed meshed HVDC networks include both converters and DC circuit breakers, and the fault currents experienced and therefore the capacity requirement of circuit breakers are dependent on the topology of converters used on the network.
Green, TC   +3 more
core   +1 more source

An Overview of High‐Temperature Superconducting Cables in DC Systems: Unlocking Potential for High‐Voltage DC Networks

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper provides an overview of high‐temperature superconducting (HTS) cables in DC systems, with a focus on their deployment in high‐voltage DC (HVDC) networks. The assessment of HTS cable properties—such as extremely low electrical resistance, high current‐carrying capacity and a compact geometry—and their comparison with those of ...
Mohammad Hossein Mousavi   +2 more
wiley   +1 more source

Optimizing the roles of unit and non-unit protection methods within DC microgrids [PDF]

open access: yes, 2012
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements.
Burt, Graeme   +4 more
core   +4 more sources

Type Tests for Hybrid HVDC Breakers: a Technical Feasible Solution

open access: yes, 2023
In the coming years, the use of the HVDC circuit breakers will become a necessity in the “grids of the future” (basically multi-terminal HVDC grids). An obliged step is to test such equipment before to install it on the grids.
Roy Maarten Nijman   +4 more
core  

Analysis of Out‐of‐Step Oscillation Centre Migration Under Increasing Renewable Energy Penetration in Large‐Scale Power Systems

open access: yesIET Smart Energy Systems, Volume 2, Issue 3, Page 181-190, September 2026.
Increasing renewable penetration causes out‐of‐step oscillation centres to migrate away from renewable integration points. Two distinct migration modes—continuous drift and large‐range jumps with instability‐mode changes—are identified, providing guidance for adaptive splitting protection in future power systems.
Changsheng Chen   +8 more
wiley   +1 more source