Results 1 to 10 of about 39 (39)
An architecture‐based framework compares HTS‐HVDC and conventional VSC‐HVDC under matched receiving‐end service and contingency requirements. Equal and alternative module ratings reveal how installed reserve, conductor price and technology‐specific construction costs shape the additional conventional corridor expenditure required for lifecycle‐cost ...
Alireza Ganjovi, Saman A. Gorji
wiley +1 more source
Phasing Out Coal Power Through Cross‐Border Renewable Energy Trade in the Asia‐Pacific
ABSTRACT Coal remains the backbone of electricity generation in the Asia‐Pacific region, accounting for half of total regional output and two‐thirds of global coal‐fired capacity. The substantial environmental and public‐health externalities of coal highlight the urgent need to accelerate the renewable energy transition.
Bin Lu +6 more
wiley +1 more source
ABSTRACT Intelligent computing loads, which are characterised by high‐power density and impulsive, pose a significant challenge to high‐power impact resilience and fast dynamic response capability of the internal power supply system in data centres. To tackle this challenge, this paper proposes an 800 V HVDC distribution architecture integrated with ...
Yanlin Song +4 more
wiley +1 more source
ABSTRACT Damage degradation of epoxy resin insulating materials by free radicals triggered by the ultraviolet irradiation environment at high altitude has become a key issue that restricts the reliability of the bridge arm reactor at high altitude.
Liang Zou +5 more
wiley +1 more source
Deterioration Law of Mechanical Properties of Insulation Pressboard Under Multifield Coupled Ageing
ABSTRACT Converter transformers can experience progressive deterioration of their oil–pressboard insulation under elevated temperature, combined AC–DC electrical stress and persistent mechanical vibration. This study investigates how mechanical vibration affects the mechanical properties of insulation pressboard and clarifies the associated microscopic
Jiayi Chen +5 more
wiley +1 more source
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley +1 more source
ABSTRACT To solve the ion‐flow field of ultrahigh‐voltage direct current (UHVDC) transmission lines under strong‐wind scenarios, the multiple relaxation time lattice Boltzmann method (MRT‐LBM) is adopted. Compared with previous ion‐flow studies predominantly based on the single relaxation time LBM, the MRT‐LBM framework provides improved numerical ...
Ting Zhu, Rongbin Wang, Haidong Wang
wiley +1 more source
ABSTRACT Polypropylene (PP) is recyclable and offers excellent insulation, but it requires elastomer blending for cable applications due to its brittleness. Although polyolefin elastomer (POE) enhances mechanical properties, it degrades dielectric performance, particularly at high temperatures.
Guangwei Zhang +7 more
wiley +1 more source
A multi‐objective scheduling model is constructed with the objectives of minimising the operating cost of the photovoltaic‐storage flexible DC microgrid and minimising the standard deviation of the interactive power with the main grid, while relevant operational constraints are established.
Cheng Hui Lin +4 more
wiley +1 more source
Fault Diagnosis Method for DC Current Transformers Based on Deep Learning Hybrid Model
Aiming at the problems of scarce fault samples, strong noise interference and complex feature coupling in the current DCCT fault diagnosis process, a DCCT fault diagnosis method based on a hybrid deep learning model is proposed. The performance of the proposed method is verified through experiments.
Cai Xu +4 more
wiley +1 more source