Results 81 to 90 of about 18,543 (264)
The characteristics of the dynamic reactive power demand of a hybrid multi-infeed HVDC transmission system during the post-fault recovery period are analyzed and a coordinated control strategy to improve the fault recovery characteristics of the hybrid ...
Bingjie Jin +7 more
doaj +1 more source
Minimum Frequency and Voltage Stability Constrained Unit Commitment for AC/DC Transmission Systems
An increased use of the high-voltage direct current (HVDC) technologies can have important effects on frequency performance and voltage stability of the receiving-end grid during normal operation as well as during blocking failure.
Ningyu Zhang, Qian Zhou, Haoming Hu
doaj +1 more source
Single-end Protection Scheme Based on Transient Power Waveshape for Hybrid HVDC Transmission Lines [PDF]
Feiyang Dai, Zexin Zhou, Xingguo Wang
openalex +1 more source
Power balancing and dc fault ride through in DC grids with dc hubs and wind farms [PDF]
Acknowledgment This project was funded by European Research Council under the Ideas program in FP7; grant no 259328, 2010.Peer ...
Jovcic, Dragan, Lin, Weixing
core +1 more source
ABSTRACT To solve the complex scenarios, such as multimodal noise, bad measurement data and sudden load changes, in the power system, the enhanced generalised cross correlation entropy unscented Kalman filter (EnGCCE‐UKF) method is proposed in this paper.
Liangzheng Wu +3 more
wiley +1 more source
Review of high voltage direct current cables
Increased renewable energy integration and international power trades have led to the construction and development of new HVDC transmission systems. HVDC cables, in particular, play an important role in undersea power transmission and offshore renewable ...
Cao, Junzheng +5 more
core +1 more source
Shielding of Unconventional High Surge Impedance Loading Transmission Lines
This paper focuses on determining the optimal location and number of shield wires for a novel‐designed unconventional high surge impedance loading line. This line has a much lower surge impedance than conventional lines, raising key questions on the location of shield wires to meet an acceptable shielding failure rate (SFFOR).
Saikat Chowdhury, Mona Ghassemi
wiley +1 more source
The Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability
This paper explains the working principles, supported by simulation results, of a new converter topology intended for HVDC applications, called the alternate arm converter (AAC).
Critchley, R +6 more
core +1 more source
Multi-pole voltage source converter HVDC transmission systems [PDF]
This study connects several modular multilevel converters to form multi-pole voltage source converter highvoltage dc (VSC-HVDC) links which are suited for bulk power evacuation, with increased resiliency to ac and dc network faults.
Ased, Grain Philip, Williams, Barry W.
core +1 more source
Multi‐Layer MTDC Protection: Design and Simulation Assessment
This study proposes a novel multi‐layer protection architecture for multi‐terminal DC systems that separates fault current‐limiting and interruption functions. By combining a thyristor‐based fault current limiter with an active resonance circuit breaker, the scheme significantly reduces peak fault currents and di/dt stress, enabling a more compact ...
Jong‐Geon Lee +3 more
wiley +1 more source