Results 101 to 110 of about 21,810 (200)
Proposing a Rule for VSC-HVDC Optimal Placement to Improve Transient Stability of Power System [PDF]
Transient stability indicates the system's ability to dampen the rotor oscillations of synchronous generators after severe faults. The transient instability causes considerable damage to the generator and reduces the production capacity in the network ...
Ali Abrishami Moghaddam +2 more
doaj +1 more source
A Two-Dimensional Cloud Model for Condition Assessment of HVDC Converter Transformers
Converter transformers are the key and the most important components in high voltage direct current (HVDC) power transmission systems. Statistics show that the failure rate of HVDC converter transformers is approximately twice of that of transformers in ...
Linjie Zhao +4 more
doaj +1 more source
Intelligent Sensors for dc Fault Location Scheme Based on Optimized Intelligent Architecture for HVdc Systems. [PDF]
Yousaf MZ +4 more
europepmc +1 more source
Analytical Design of HVDC Link Control System
The parameters of the minor-loop constant-current controller of a hvdc converter station using a mathematical model is described. Effects of the parameters on the dynamic response characteristics of the converter station are analyzed by the root locus method.
S. Koseki, E. Masada
openaire +2 more sources
Modeling of Efficient Control Strategies for LCC-HVDC Systems: A Case Study of Matiari-Lahore HVDC Power Transmission Line. [PDF]
Ahmed A +8 more
europepmc +1 more source
New two chamber transfer switch for 6500 A commutation current
HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmission systems, which increased to 6,400A ...
Lutz-Rüdiger Jänicke +4 more
doaj +1 more source
A hybrid multilevel converter for medium and high voltage applications [PDF]
This paper investigates the suitability of the hybrid multilevel converter for medium and high voltage application. The converter operation, modulation, and capacitor voltage balancing method are described in detail.
Adam, Grain Philip +4 more
core
This paper deals with the problem of trajectory tracking of a class of bilinear systems with time--varying measurable disturbance. A set of matrices {A,B_i} has been identified, via a linear matrix inequality, for which it is possible to ensure global ...
Bergna, G. +5 more
core +4 more sources
{"references": ["Summary of Impacts of the New Guidelines of the International Commission on Non-Ionizing Radiation Protection on Power System Operation. International Commission on Non-Ionizing Radiation Protection (INIRP). Hydro-Quebec. 1999.", "High-Voltage DC transmission \u2013 a power electronics workhouse. N.G. Ingrain. IEEE Spectrum, April 1996.
Smko Zangana, Ercelebi, Ergun
openaire +1 more source
Electrical withstand performance of Malaysian based palm oil under influence of HVDC stress [PDF]
Overvoltage is a phenomenon where electrical waveform applied to circuit or device exceeds normal operating parameters. The sources of overvoltage are often unpredictable and can lead to permanent degradation, failure or temporary malfunction of devices ...
Baharom, Md Nor Ramdon +5 more
core

