Results 181 to 190 of about 2,067 (225)
Some of the next articles are maybe not open access.

Fault detection and localization for HVDC transmission lines

2018 Simposio Brasileiro de Sistemas Eletricos (SBSE), 2018
This paper evaluates a new method for faults detections in transmission lines in HVDC systems. The proposed method uses voltage and current synchronized data. The HVDC systems are simulated using MATLABĀ® software. The method for detection of faults in transmission line uses a self-adaptive threshold and presents a redundancy, which allows the detection
Y. Melo, W. Neves, D. Fernandes
openaire   +1 more source

Neutral Line Protection System for HVDC Transmission

IEEE Transactions on Power Delivery, 1986
This paper described the principle of fault detection and its simulator study, principal circuitry, field test results and field performance records on the neutral line protection system for an HVDC transmission system. In the protection system, 125 Hz ac current injected to the neutral line is utilized as a pilot current to detect the neutral line ...
Y. Kato   +5 more
openaire   +1 more source

Fault-Line Identification of HVDC Transmission Lines by Frequency-Spectrum Correlation Based on Capacitive Coupling and Magnetic Field Sensing

open access: yesIEEE Transactions on Magnetics, 2018
The protection system of high-voltage direct-current (HVDC) system must detect, identify, and isolate the fault quickly to keep the system stable by only isolating the components that are under fault, while leaving the rest of the network in operation ...
Ke Zhu, Philip W T Pong
exaly   +2 more sources

A Fault Location Method for HVDC Transmission Lines

Applied Mechanics and Materials, 2014
A fault location method for HVDC (High Voltage Direct Current) transmission lines is proposed in this paper, using voltages and currents measured at two terminals of dc lines in time domain. Fault traveling waves propagate from the fault point to both terminals along the faulted line.
Lu Hua Xing, Qing Chen, Bing Lei Xue
openaire   +1 more source

A novel protection scheme for HVDC transmission line

2011 International Conference on Advanced Power System Automation and Protection, 2011
The formation of the transient capacitive current and its effects on the HVDC transmission line differential protection is analyzed based on the wave propagation principle in this paper. The magnitude of capacitive current in the transient process of DC line fault is directly proportional to the time difference of fault signal travelling to both ...
XiaoDong Zheng   +6 more
openaire   +1 more source

A protection system for long HVDC transmission lines

Proceedings of the Inaugural IEEE PES 2005 Conference and Exposition in Africa, 2006
A recent review of the currently used HVDC line protection systems clearly indicated that these systems were not adequately equipped to protect HVDC schemes with extremely long HVDC transmission lines. Therefore, considering the increase in HVDC transmission line lengths projected for the future HVDC schemes, it is of vital importance that some type of
D. Naidoo, N.M. Ijumba
openaire   +1 more source

EM Environmental Evaluation of HVDC Transmission Lines

The 2006 4th Asia-Pacific Conference on Environmental Electromagnetics, 2006
Due to the high voltage operation of transmission lines, corona discharge phenomena are quite common around AC and DC transmission lines. A large amount of positive and/or negative ions are generated during the corona processes. The effects of corona space charge arising from HVDC transmission lines are much more significant than that in AC ...
Huiliang Zhao   +3 more
openaire   +1 more source

Shielding Effect of HVAC Transmission Lines on the Ion-Flow Field of HVDC Transmission Lines

IEEE Transactions on Power Delivery, 2013
The HVDC and HVAC transmission lines running on the same tower is a promising technology to improve the transmission capacity of an existing corridor. The ions generated by corona discharge of HVDC transmission lines will strengthen the ground-level electric field, which may endanger human exposure.
Xiangxian Zhou   +7 more
openaire   +1 more source

The fault location method for HVDC transmission line

2006 China International Conference on Electricity Distribution (CICED 2006), 2006
The integrative fault location approach which combines the single terminal, dual terminals traveling wave location method and traditional fault location method has been brought forward. The new approach could fetch up the deficiency of the dual terminals traveling wave location method. The possible unsuccessful case of traveling wave fault location has
null Yongchang Zhai, null Haifeng Zhang
openaire   +1 more source

Conductor surface voltage gradients on bipolar HVDC transmission lines

IEEE Transactions on Power Apparatus and Systems, 1976
The method of successive images is used to obtain accurate values of maximum surface voltage gradients for practical HVdc transmission lines. The results are presented in the form of graphs of gradient factors as a function of the principal line parameters.
Morris, R. M., Maruvada, P. S.
openaire   +2 more sources