Results 41 to 50 of about 757 (163)

Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing

open access: yesHigh Voltage, EarlyView.
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu   +7 more
wiley   +1 more source

Development of ± 550 kV DC GIS Basin Insulator

open access: yesHigh Voltage, EarlyView.
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao   +9 more
wiley   +1 more source

A Thermal‐Dependent Conductivity Coating for Surface Charge and Electric Field Mitigation Under Electrothermal Coupling Field

open access: yesHigh Voltage, EarlyView.
ABSTRACT The problem of gas–solid interface charge accumulation is an important reason for distorting the surface electric field and then inducing surface discharge. The temperature gradient distribution formed on the spacer during the operation of a gas‐insulated transmission line (GIL) will aggravate the surface charge accumulation, further ...
Jianyi Xue   +6 more
wiley   +1 more source

Long‐term statistics of corona loss of HVDC transmission line

open access: yesThe Journal of Engineering, 2019
Corona loss is one of the electromagnetic environment parameters of high‐voltage direct current (HVDC) transmission lines. So far many countries have carried out researches and measurements on it. In 2008, UHVDC test lines were established in the National Engineering Laboratory for UHV Technology (Kunming) at the altitude about 2100 m.
Zhanqing Yu   +4 more
openaire   +2 more sources

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

An Overview of High‐Temperature Superconducting Cables in DC Systems: Unlocking Potential for High‐Voltage DC Networks

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper provides an overview of high‐temperature superconducting (HTS) cables in DC systems, with a focus on their deployment in high‐voltage DC (HVDC) networks. The assessment of HTS cable properties—such as extremely low electrical resistance, high current‐carrying capacity and a compact geometry—and their comparison with those of ...
Mohammad Hossein Mousavi   +2 more
wiley   +1 more source

Ion‐Flow Field Modelling of ± 1100 kV Transmission Lines Under Strong‐Wind Scenarios Using the Multiple Relaxation Time Lattice Boltzmann Method

open access: yesHigh Voltage, EarlyView.
ABSTRACT To solve the ion‐flow field of ultrahigh‐voltage direct current (UHVDC) transmission lines under strong‐wind scenarios, the multiple relaxation time lattice Boltzmann method (MRT‐LBM) is adopted. Compared with previous ion‐flow studies predominantly based on the single relaxation time LBM, the MRT‐LBM framework provides improved numerical ...
Ting Zhu, Rongbin Wang, Haidong Wang
wiley   +1 more source

Current‐Carrying Characteristics of High‐Voltage Land Cables With Different Grounding Methods for Low‐Frequency AC Transmission

open access: yesHigh Voltage, EarlyView.
ABSTRACT Low‐frequency AC transmission holds promise for high‐voltage land cables, but its ampacity is significantly influenced by cable grounding methods and other structural factors. To explore the specific low‐frequency current‐carrying characteristics of high‐voltage land cables, this paper conducts a thorough theoretical analysis of the coupling ...
Yongpei Li   +4 more
wiley   +1 more source

Power system decarbonisation with Global Energy Interconnection – a case study on the economic viability of international transmission network in Australasia

open access: yesGlobal Energy Interconnection, 2018
The electric energy system in Indonesia is undergoing with the challenges of fast-increasing electricity demand, carbon constraints, and rising costs. Using our model of the Australian and Indonesian electrical grids (either separately or interconnected)
Changlong Wang   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy