Results 81 to 90 of about 2,067 (225)

Proposing a Rule for VSC-HVDC Optimal Placement to Improve Transient Stability of Power System [PDF]

open access: yesInternational Journal of Research and Technology in Electrical Industry
Transient stability indicates the system's ability to dampen the rotor oscillations of synchronous generators after severe faults. The transient instability causes considerable damage to the generator and reduces the production capacity in the network ...
Ali Abrishami Moghaddam   +2 more
doaj   +1 more source

SBOA‐Based Multi‐Level Parallel Fuzzy Controller for AGC of Multi‐Area Power Systems With Renewable Energy and Storage

open access: yesEngineering Reports, Volume 8, Issue 6, June 2026.
Secretary Bird Optimization Algorithm (SBOA)‐optimized parallel two‐level fuzzy tilt‐derivative (TLF‐TDN) controller enhances automatic generation control in multi‐area hydro–thermal–wind systems with AC/HVDC links and SCESS. It effectively suppresses frequency deviations and tie‐line oscillations, ensuring faster settling, improved dynamic stability ...
Getaneh Mesfin Meseret   +1 more
wiley   +1 more source

Ann based Shortcoming Area in HVDC Transmission Line

open access: yesInternational Journal of Innovative Technology and Exploring Engineering, 2019
This paper is to ponder the use of Neural systems for shortcoming discovery and area in HVDC framework. The proposed Neural system learns examples and relationship on transient information. The Back-propagation algorithm has the ability to match map complex and nonlinear input - output behavior.
C. Poongothai, K. Gayathri
openaire   +1 more source

Construction and Application of Online Vibration Frequency Response Analysis Method for Converter Transformer Winding

open access: yesHigh Voltage, Volume 11, Issue 3, Page 646-655, June 2026.
ABSTRACT The harmonic current and vibration of a converter transformer are effective pieces of information for detecting mechanical faults in the winding. In this paper, the ratio of vibration acceleration to the current squared is defined as the vibration frequency response function (VFRF) of the winding, and then, a novel online vibration frequency ...
Shuyu Wu, Fan Zhang, Shengchang Ji
wiley   +1 more source

Single Pole-to-Ground Fault Analysis of MMC-HVDC Transmission Lines Based on Capacitive Fuzzy Identification Algorithm

open access: yesEnergies, 2020
The probability of a single pole-to-ground fault in high voltage direct current (HVDC) transmission lines is relatively high. For the modular multilevel converter HVDC (MMC-HVDC) systems, when a single pole-to-ground fault occurs, the fault current is ...
Hongchun Shu   +4 more
doaj   +1 more source

A Novel Converter Transformer DAM‐LSTNet Vibration Generation Model for Data Imbalance Identification

open access: yesHigh Voltage, Volume 11, Issue 3, Page 620-632, June 2026.
ABSTRACT Converter transformer vibration failures, primarily because of winding and core vibrations, severely impact the safe operation of high voltage direct current (HVDC) systems. These vibrations are influenced by voltage and current, and are transmitted through transformer oil and structural components to the tank. Current numerical models fail to
Peiyu Jiang, Fanghui Yin, Liming Wang
wiley   +1 more source

Continuous Operation of Wind Power Plants under DC Line Faults in Multi-Circuit HVDC Transmission System

open access: yes, 2021
This paper focuses on the multi-circuit HVDC transmission system which can localize DC line faults. The conventional method requires to shutdown and restart the wind power plants after the DC line faults, resulting in the long-term suspension of the ...
佐野, 憲一朗   +3 more
core  

Adaptability Analysis and Countermeasures for Distance Protection of AC Transmission Lines Connected LCC-HVDC Inverter Station

open access: yesZhongguo dianli
The AC transmission line fault near the LCC-HVDC inverter station might lead to commutation failure. And fault voltage and current waveforms would be distorted. It will have an adverse effect on the performance of fundamental power frequency phasor based
Huixin LI   +4 more
doaj   +1 more source

An on-line power/voltage stability index for multi-infeed HVDC systems

open access: yesJournal of Modern Power Systems and Clean Energy, 2019
High-voltage direct current (HVDC) transmission is playing an increasingly important role in modern power systems, and the resulted power/voltage stability issue has raised widespread concern. This paper presents an on-line power/voltage stability index (
Jian Xu   +7 more
doaj   +1 more source

A novel differential protection scheme for HVDC transmission lines

open access: yesInternational Journal of Electrical Power & Energy Systems, 2018
Abstract Based on the compensation of the distributed capacitive current, a novel differential protection scheme for HVDC transmission lines was proposed in this study. According to the analysis, after voltage and current signals at both sides of the line are processed by the same low-pass filter the cut-off frequency of which is low enough, then the
Junchao Zheng   +3 more
openaire   +1 more source