Results 41 to 50 of about 1,710 (215)
HVDC power transmission technology assessment [PDF]
The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems.
Stewart, James R. +5 more
core +1 more source
Bipolar configuration is a new topology in the direct current (DC) system of photovoltaic power plants, which is topologically analogous to the bipolar configuration utilised in High‐Voltage Direct Current power transmission systems. DC cable length and copper usage are reduced by 50% using a bipolar configuration.
Duško M. Tovilović +2 more
wiley +1 more source
Control of a VSC-HVDC Operating in Parallel with AC Transmission Lines
As part of an analysis of a VSC-HVDC operating in parallel with AC transmission lines, this paper presents an adaptive control of VSC-HVDC that allows the device: to provide voltage support by means of reactive control at both ends; to damp power ...
H. Latorre +5 more
core +1 more source
PMU‐Based Wide Area Monitoring With Machine Learning to Prevent Blackouts in Bangladesh Power System
A Unified Real‐time Dynamic State Measurements (URTDSM) system with PMU and Phasor Data Concentrator (PDC) deployment plan has been proposed to avoid blackout in the Bangladeshi power system. Machine learning has been used to process data from PMU to identify abnormal events. ABSTRACT The electrical power system must be trustworthy and secure enough to
Imi Bintey Fariha Rahman +5 more
wiley +1 more source
New two chamber transfer switch for 6500 A commutation current
HVDC transfer switches are used in different locations in electrode lines of HVDC transmission systems for their reconfigurations. They have to carry and commutate currents to the overload currents of HVDC transmission systems, which increased to 6,400A ...
Lutz-Rüdiger Jänicke +4 more
doaj +1 more source
Variance‐Empirical Mode Decomposition Method for Fault Detection in MMC‐HVDC Transmission Lines
A variance‐embedded empirical mode decomposition (VEMD) method is proposed for fast and accurate fault detection in MMC‐HVDC transmission lines. By combining variance analysis with EMD, the method reliably detects various faults without communication links and remains robust to noise and non‐fault transients.
Seyed Amir Hosseini, Behrooz Taheri
wiley +1 more source
Tato bakalářská práce si klade za cíl poskytnout základní přehled HVDC systémů, které jsou v současnosti celosvětově využívány a jejich srovnání se systémy HVAC.
Radek Wipplinger
core
During regular operation of the SuedLink at a load ≤75 %, the average increase in temperature in the plowing horizon is expected to be less than 1.6°C in the soils along the route in Southwest Germany. ABSTRACT Background The SuedLink was planned as a high‐voltage direct‐current underground cable route. The construction itself is a massive intervention
Joachim Ingwersen +10 more
wiley +1 more source
A Novel Protection Scheme for MMC-HVdc Transmission Lines Based on Cross-Entropy of Charge
MMC-HVdc transmission system has become the mainstream of power construction and plays an increasingly important role in the power system. However, the dc line fault results in shutting down of the converters, which can greatly endanger the security of ...
Chuanjian Wu, Dahai Zhang, Jinghan He
doaj +1 more source
A Novel Digital Twin Platform for Accelerating Power Systems Restoration
Hardware Architecture Design of DT System in Laboratory. ABSTRACT With the global energy structure transforming towards the goal of net zero emissions, the penetration of an inverter‐based resource (IBR) in power systems is increasing. This transformation poses two critical challenges: the system post blackout restoration process becomes extremely ...
Yiliang Fan +8 more
wiley +1 more source

