A Review on Hybrid Circuit Breakers for DC Applications
Direct current (dc) power system protection presents a major challenge due to its unique characteristics, namely the absence of natural zero current crossing points. Thanks to their features, dc protection devices allow the safe commutation of the fault current.
Ana Rafaela Figueiredo Bento +2 more
openaire +2 more sources
Features of fault transient's in generator network of powerful electric power stations
THE PURPOSE. To consider the problems of generator circuit breaker. To consider the problems of high degree of asymmetry of short-circuit current and long delayed current zeros in detail. Propose methods for solving these problems. Develop the equivalent
E. P. Safonov, V. Ya. Frolov
doaj +1 more source
With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability,
Muhammad Junaid +6 more
doaj +1 more source
Key stress extraction and equivalent test method for hybrid DC circuit breaker
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological ...
Chong Gao +4 more
doaj +1 more source
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden +11 more
core +1 more source
Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X +6 more
core +1 more source
Investigation of Impulse Aging of Energy-Absorption Elements for Hybrid DC Circuit Breakers
The state of the energy-absorption branch MOV in the hybrid DC circuit breaker (DCCB) has a very important impact on the short fault breaking operation of the circuit breaker.
Xinyi Wang +6 more
doaj +1 more source
Automated post-fault diagnosis of power system disturbances [PDF]
In order to automate the analysis of SCADA and digital fault recorder (DFR) data for a transmission network operator in the UK, the authors have developed an industrial strength multi-agent system entitled protection engineering diagnostic agents (PEDA).
Davidson, E.M., McArthur, S.D.J.
core +1 more source
Research on topological structure and simulation of hybrid DC circuit breaker
At present, the hybrid DC circuit breaker (ABB company's Hybrid DC circuit breaker as the representative scheme) must be equipped with the radiator because of a long-time current passing through the power electronic devices in the load-control-switch ...
Chu Zhuang +3 more
doaj +1 more source