Power system security enhancement by HVDC links using a closed-loop emergency control [PDF]
In recent years, guaranteeing that large-scale interconnected systems operate safely, stably and economically has become a major and emergency issue.
Allaoui, Tayeb +4 more
core +2 more sources
For the hybrid multi-infeed HVDC system in which the receiving-end grid is a strong AC grid including LCC-HVDC subsystems and multiple VSC-HVDC subsystems, it has higher voltage support capability.
Tao Li, Yongli Li, Yuchen Zhu
doaj +1 more source
Modular multilevel converter with modified half-bridge submodule and arm filter for dc transmission systems with DC fault blocking capability [PDF]
Although a modular multilevel converter (MMC) is universally accepted as a suitable converter topology for the high voltage dc transmission systems, its dc fault ride performance requires substantial improvement in order to be used in critical ...
Abdelsalam, Ibrahim A. +3 more
core +2 more sources
Practical calculation of SCR of LCC-HVDC considering the role of VSC-HVDC
The accurate quantification of transmission limit and grid strength of the multi-infeed LCC-HVDC (line-commutated converter technology-based high-voltage DC) and VSC-HVDC (voltage source converter technology-based high-voltage DC) systems has become one ...
YANG Xiaolei +5 more
doaj +1 more source
Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
Hybrid ultra‐HVDC system with LCC and cascaded hybrid MMC
Nowadays, the hybrid high‐voltage direct current (HVDC) system consisting of line commutated converter (LCC) and modular multilevel converter (MMC) has become the most competitive candidate in multi‐infeed power systems. Owing to the limitation of insulated‐gate bipolar transistor's withstand voltage, the DC voltage rating of MMC is not compatible with
Ruizhang Yang +3 more
openaire +2 more sources
Enhanced Ride-Through Capability Under Rectifier-Side AC Fault for Series LCC-MMC Hybrid HVDC System
The series line-commutated converter (LCC) and modular multilevel converter (MMC) hybrid HVDC system provides a more economical and flexible alternative for UHVDC transmission. With the LCC DC voltage reduction, no current cut-off will occur under slight
Xiaodong Li, Zheng Xu, Zheren Zhang
semanticscholar +1 more source
Multi-infeed HVDC/AC power system modeling and analysis with dynamic phasor application [PDF]
In this paper, dynamic phasor method has been applied to HVDC transmission system and FACTS device modeling. A hybrid-model simulation algorithm is suggested for transient stability analysis with HVDC transmission system and FACTS devices in dynamic ...
Cai, Z, Liu, H, Ni, Y, Zhu, H
core +1 more source
An approach to suppress low-frequency oscillation in the hybrid multi-Infeed HVDC of mixed H2/H∞ robust-based control theory [PDF]
A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling.
Congshan Li +5 more
doaj +1 more source
National Key R&D Programme of China, Grant/ Award Number: 2016YFB0900900; National Nature Science Foundation of China (NSFC), Grant/Award Number: 51677125 Abstract A bipolar short‐circuit transient fault identification method for overhead transmission ...
Botong Li +5 more
semanticscholar +1 more source

