DC fault isolation study of bidirectional dual active bridge DC/DC converter for DC transmission grid application [PDF]
Fast isolation and detection of DC faults is currently a limiting factor in high power DC transmission grid development. Recent research has shown that the role of DC/DC converters is becoming increasingly important in solving various DC grid challenges ...
Aboushady, Ahmed A. +2 more
core +2 more sources
Active power losses distribution methods for the modular multilevel converter [PDF]
Modular Converters such as the MMC have become the new standard in VSC-HVDC applications. Their modularity has brought many industrial advantages but also increased the complexity of their operation.
Merlin, MMC, Mitcheson, PD
core +1 more source
A Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application [PDF]
The use of high voltage direct current (HVDC) circuit breakers (CBs) with the capabilities of bidirectional fault interruption, reclosing, and rebreaking can improve the reliable and safe operation of HVDC grids. Although several topologies of CBs have been proposed to perform these capabilities, the limitation of these topologies is either high on ...
Van-Vinh Nguyen +4 more
openaire +2 more sources
Offshore wind farm (OWF) is considered as a perfect zero‐carbon energy source for the future power system. However, the growing offshore distance and water depth of OWF make the OWF HVDC transmission technique a more promising solution than HVAC due to ...
Junpeng Deng +6 more
doaj +1 more source
The hybrid simulation system of hydropower generation units in islanding AC grid and its applications [PDF]
It is a trend for the large hydropower bases to transport the electricity to consuming center with High Voltage Direct Current (HVDC) transmission lines. The fault of HVDC has great significance impact on hydropower units in islanding sending AC grid. In
Zhang Shuang +3 more
doaj +1 more source
Full Bridge MMC Converter Optimal Design to HVDC Operational Requirements [PDF]
This project is funded by RTE, Paris, FrancePeer ...
Jovcic, Dragan +3 more
core +1 more source
Communication Requirements for a Hybrid VSC Based HVDC/AC Transmission Networks State Estimation
The communication infrastructure of the modern Supervisory, Control and Data Acquisition (SCADA) system continues to enlarge, as hybrid High Voltage Direct Current (HVDC)/Alternating Current (AC) networks emerge.
Motaz Ayiad +3 more
doaj +1 more source
Interlink hybrid DC circuit breaker [PDF]
—To protect HVDC grids from DC faults, the concept of a hybrid DC circuit breaker is widely accepted due to its low conduction losses and fast interruption speed.
Li, Chuanyue, Liang, Jun, Wang, Sheng
core +1 more source
HYBRID AC/MT-HVDC TRANSMISSION LINES AND ITS EFFECTIVE OPERATION USING ENHANCED-FISH SWARM OPTIMIZER [PDF]
Multi-Terminal-High Voltage Direct Current (MT-HVDC) transmission lines are used to transmit electricity over long distances with lower losses compared to traditional Alternating Current (AC) transmission lines.
Prabhat Kumar Srivastava +5 more
doaj +1 more source
Cost and losses associated with offshore wind farm collection networks which centralise the turbine power electronic converters [PDF]
Costs and losses have been calculated for several different network topologies, which centralise the turbine power electronic converters, in order to improve access for maintenance.
Anaya-Lara, Olimpo, Parker, Max
core +1 more source

