Estimation of hydrogenerator rotor dynamic thermal margine [PDF]
Field winding temperature of the synchronous generator is one of limiting factors shaping generator PQ capability curve. Therefore of great operational importance is to have information about this temperature estimated with the utmost accuracy. It can be
Klasnić Ilija +4 more
doaj +2 more sources
Practical Modal Analysis of a Prototyped Hydrogenerator [PDF]
The vibration on the stator core of hydrogenerators caused by electromagnetic forces is an important factor affecting the reliability and long-lasting operation of a machine.
Allan de Barros +3 more
doaj +2 more sources
The technology of restoration hydrogenerator rotor shape
The object of research in this article is the change in the rotor shape during the operation of hydraulic units. The subject of study in this article is the design and geometric state of the shape of a rotor with irregular geometry of hydraulic ...
Pavlo Makarov
doaj +2 more sources
Thermal management is often considered a bottleneck in the pursuit of the next generation hydrogenerator in the electric power system. Overheating of the complex rotor parts has become one of the main problems affecting safe and stable hydrogenerator ...
Han Jichao +5 more
doaj +1 more source
Ventilation cooling design is one of the key technologies during the design of large hydrogenerator. With the increase of hydrogenerator capacity, the overheating problem of rotor region become more and more serious.
Han Jichao +8 more
doaj +1 more source
Stress-Strained State of the Thrust Bearing Disc of Hydrogenerator-Motor
In this article, the main causes of vibration in the thrust bearing of hydrogenerator motors rated 320 MW are considered. The main types of internal and surface defects that appear on the working surface of the thrust bearing disc during long-term ...
Oleksii Tretiak +7 more
doaj +1 more source
In this paper, a three-dimensional turbulent fluid dynamics numerical model of a 311 MVA full hydroelectric power plant unit is made, using the finite element method, to study and understand the ozone transport mechanisms inside the enclosured electric ...
Rodrigo M. S. de Oliveira +4 more
doaj +1 more source
This article presents a comparative analysis of the technical and economic efficiency of a derivation-type inverter micro hydro power plant with an energy storage system and an auto-ballasted micro hydro power plant.
B. V. Lukutin, M. M. Popov
doaj +1 more source
The paper presents results of analysis of the influence of the thickness of the dielectric substrate of a capacitive beating sensor, the electrodes of which are made of foil dielectric type FR4, on the transformation function of the sensor by methods of ...
В.О. Березниченко +1 more
doaj +1 more source
Axial Vibration Analysis of Thrust Support of Vertical Hydrogenerator Unit [PDF]
Axial vibration is the main accident that affects the normal function of the vertical hydro-generator unit and endangers the use of the unit. There are many reasons for the axial vibration of the unit.
Long Yuanlin, Ye Yuping
doaj +1 more source