A Digital Governor for Hydrogenerators

IEEE Transactions on Energy Conversion, 1988
The authors describe the development and testing of a microcomputer-based digital governor for hydrogenerators. The digital governor was shown to approximate the control function of existing analog controllers. This task was performed as a first step to future work intended to utilize the versatility of microcomputers in effecting more sophisticated ...
L Wozniak
exaly   +2 more sources

Maximum-Slew-Rate Control for Hydrogenerators

open access: yesJournal of Engineering for Gas Turbines and Power, 1987
Traditionally, speed control of hydrogenerators has been implemented by analog proportional-plus-integral control of speed error. With digital controllers, nonlinear, adaptive control strategies may be implemented to achieve improved systems response. This paper develops a control scheme which responds to perturbations by moving wicket gates at their ...
J. Jaeger, L. Wozniak
openaire   +2 more sources

Determination of the Leakege Parameters of Synchronous Hydrogenerators

2020 21st International Symposium on Electrical Apparatus & Technologies (SIELA), 2020
An application of FEM for studying the leakage of stator slots of synchronous hydrogenerators is presented. The approach presented takes into account the saturation of the stator teeth and the mutual influence of the current in adjacent stator slots.
Vultchan Gueorgiev, Plamen Rizov
exaly   +2 more sources

Optimal PID Gain Schedule for Hydrogenerators-Design and Application

IEEE Transactions on Energy Conversion, 1989
The development and testing of a digital gain switching governor for hydrogenerators are described. Optimal gains are found at different load points by minimizing a quadratic performance criterion prior to controller operation. During operation, the gain sets are switched in depending on gate position and speed error magnitude.
L Wozniak
exaly   +2 more sources

Asynchronous operation of hydrogenerator calculation verification by tests on old hydrogenerator in power plant

Proceedings of the 12th IEEE Mediterranean Electrotechnical Conference (IEEE Cat. No.04CH37521), 2004
The extended testing of hydrogenerator (rated 35 MVA) was made because the generators working age expired and it was going to be replaced with new one. This was the perfect opportunity to do some specific and not usual testing. The complicated testing plan was designed in order to enable recording as much relevant data as possible (electrical ...
Z. Zebic, Z. Maljkovic, M. Pavlica
openaire   +1 more source

Experimental model of a hydrogenerator with static excitation

2011 IEEE EUROCON - International Conference on Computer as a Tool, 2011
In this paper is presented an experimental model for an hydro aggregate with synchronous generator having static excitation. The model was designed and achieved in the laboratory at reduced scale, of 12 kVA, using a VI — LabVIEW environment. With the help of this model there might be experimentally studied the dynamic conditions of the real hydro ...
Marius Biriescu   +6 more
openaire   +2 more sources

New Design of Hydrogenerator Poles.

RE&PQJ, 2023
HydrogeneratorThe excess of reactive power generated by power transmission lines is the reason for impermissible increase of voltage at the terminals of the length power transmission lines for consumers. One of the alternative decisions for this problem could become at the hydropower station hydrogenerators, specially designed or reconstructed for ...
openaire   +1 more source

Dynamics of Large Hydrogenerators

1996
Based on experimental data, this paper shows that the mathematical models of large hydrogenerators, used to preview the dynamic behavior at the design phase or as a predictive maintenance tool at the operation phase, must include the effects of the stiffness and damping forces of the oil film in the guide bearings.
G. C. Brito   +2 more
openaire   +1 more source