Purpose: To compare surface alterations between preloaded and manually loaded intraocular lens. Methods: Scanning electron microscope was utilized to evaluate surface alteration and deposits in four different types of intraocular lenses: preloaded ...
Ahmed Hasan Eldoghaimy +3 more
core +1 more source
Acute clouding of trifocal lens during implantation: a case report
Background Intraoperative IOLs clouding of several kinds of hydrophilic acrylic intraocular lenses (IOLs) have been reported due to temperature changes. This phenomenon reported previously occurred in cold countries and during the winter months. However,
Qian Liu +4 more
doaj +1 more source
Innovative Drug Delivery Systems for the Treatment of Glaucoma
This review aims to provide a comprehensive overview of current topical drug delivery strategies for ocular hypotensive agents in glaucoma therapy. Additionally, it discusses the potential impact of emerging nanotechnological and biomaterial‐based systems in shaping the future of ophthalmic drug delivery, with an emphasis on enhancing efficacy, safety,
Jing Chu +9 more
wiley +1 more source
Bio‐based and (semi‐)synthetic zwitterion‐modified novel materials and fully synthetic next‐generation alternatives show the importance of material design for different biomedical applications. The zwitterionic character affects the physiochemical behavior of the material and deepens the understanding of chemical interaction mechanisms within the ...
Theresa M. Lutz +3 more
wiley +1 more source
Effect of four different intraocular lenses on posterior capsule opacification
AIM: To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates.
Rahmi Duman +3 more
doaj +1 more source
We systematically summarize how each scale dictates fundamental choices in design feature, manufacturing technology, driving mechanism, and control strategy, which are inherently governed by scale‐dominated physical principles. Furthermore, the application of scale‐determined operation modes of microrobots across different stages of medical ...
Hang Yin +3 more
wiley +1 more source
Patel NA, Shah P, Yannuzzi NA, et al. Clin Ophthalmol. 2018;12:2145–2148. The intraocular lens (Akreos AO60) studied in this paper is made of hydrophilic acrylic material instead of hydrophobic acrylic. Therefore, the title of
Patel NA +14 more
doaj
Designing Scalable Mechano‐Virucidal Nanostructured Acrylic Surfaces for Enhanced Viral Inactivation
Can a surface be designed to physically break viruses? This study explores how nanoscale geometry—specifically the spacing of tiny pillars—can determine whether viruses remain intact or rupture. Using flexible acrylic and a scalable fabrication process, the authors develop nanopillared, transparent surfaces that show strong antiviral activity without ...
Samson W. L. Mah +14 more
wiley +1 more source
The purpose of the present work is to designate the synthesis of innovative soft silicone hydrogel contact lenses founded on Acrylic acid (AA),N,N dimethylacrylic amide (DMA),and 1-vinyl 2- pyrolidone(NVP) was polymerized via free fundamental ...
a Chemical Engineering Department - Faculty of Engineering – University of Al-Qadisiyah-Iraq
doaj +1 more source
Capsule contraction syndrome with a microincision foldable hydrophilic acrylic intraocular lens: two case reports and review of the literature. [PDF]
Here we present 2 cases of capsule contraction syndrome (CCS). In both cases, a hydrophilic acrylic Akreos MI60 (Bausch and Lomb) intraocular lens (IOL) was implanted in the capsular bag through microincision cataract surgery, and the literature on the ...
Balestrazzi A +5 more
europepmc +2 more sources