Results 31 to 40 of about 6,262 (261)

From Shear to Sound: Mechanics–Acoustics Mapping of TPMS Lattices

open access: yesAdvanced Engineering Materials, EarlyView.
Triply periodic minimal surface (TPMS) lattices are mapped across mechanical and acoustic performance, revealing that descriptors validated in compression fail under shear. First‐time comparison with trusses included. A transition from porous to resonance‐driven absorption emerges at 25% density.
Lucía Doyle   +3 more
wiley   +1 more source

CALCULATION OF COMBINED HYDROSTATIC BEARINGS OF DOUBLE TYPE AT STATIONARY EXTERNAL LOAD

open access: yesАвіаційно-космічна техніка та технологія, 2017
The relevance of the application of combined hydrostatic bearings of the twin type in various units and power plants is shown, the loads in which reach ten tons.
Владимир Иосифович Назин
doaj   +1 more source

A Dislocation Perspective on Strength and Toughness in Ceramics

open access: yesAdvanced Engineering Materials, EarlyView.
Dislocations in ceramics enjoy a long but yet under‐appreciated history. The three research waves for dislocations in ceramics highlight the topic evolution over the last 90 years. This review focuses on the impact of dislocation on strength and toughness in ceramics.
Xufei Fang
wiley   +1 more source

ANALYSIS OF BEARING PERFORMANCE OF HYDRODYNAMIC AND HYDROSTATIC BALL BEARINGS UNDER INTERFACE SLIP BASED ON ORIFICE THROTTLING

open access: yesJixie qiangdu, 2022
Due to study the influence of interfacial slip on the bearing capacity of hydrostatic and hydrostatic ball bearings with small orifice throttling, the Reynolds equation of ball bearings considering interfacial slip was established based on the linear ...
ZHOU YiHao, SHEN JingFeng, CHEN YuFei
doaj  

Advanced Electron Microscopy and Microcomputed Tomography Analysis of Single‐Crystal Ni‐Base Superalloys After Short‐Term Multiaxial Creep

open access: yesAdvanced Engineering Materials, EarlyView.
This work studies the anisotropic behavior of circular notched tensile specimens of Ni‐base superalloy single crystals during high‐temperature tensile creep along [001], [110], and [111]. Correlative scale‐bridging imaging of specimens reveals early rupture along [110] because 1) plastic deformation proceeds faster at notch center; 2) more (brittle ...
Leonardo Agudo Jácome   +6 more
wiley   +1 more source

Standardized Effect Measures Informing Next‐Generation Strategies for Mechanical Stimulation in Cartilage Tissue Engineering

open access: yesAdvanced Healthcare Materials, EarlyView.
This systematic review quantitatively compares conventional mechanical stimulation strategies in cartilage tissue engineering across 85 heterogeneous in vitro studies. Applying standardized effect measures, meta‐analysis reveals that combined compression and shear loading optimally promotes cartilage matrix development.
Jiaqi K. Shen   +7 more
wiley   +1 more source

Hydrostatic Asymmetric Journal Gas Bearings for Largely Unbalanced Rotors of Seismic ACROSS Transmitters

open access: yesJournal of Advanced Mechanical Design, Systems, and Manufacturing, 2007
In currently working seismic ACROSS (Accurately Controlled Routinely Operated Signal System) transmitters, an unbalanced rotor with large eccentric mass, which generates elastic waves, is supported by roller bearings.
Tomohiko ISE   +4 more
doaj   +1 more source

Microgel‐Based 3D Bioprinting: A Convergent Strategy Integrating Material Design, Jamming Dynamics, and Biological Function

open access: yesAdvanced Healthcare Materials, EarlyView.
Microgel‐based 3D printed constructs represent a compelling and versatile innovation for engineering architecturally complex, dynamically remodelable, and biocompatible structures with high structural fidelity and bioactivity. By integrating material design, biofabrication, and biological function, these systems enable the development of adaptive ...
Elena Ghighină   +2 more
wiley   +1 more source

Analysis of Hydrostatic Bearing Structure Characteristics of Guide Sleeve of Electro hydraulic Servo Cylinder

open access: yesJournal of Harbin University of Science and Technology, 2020
As a typical bionic foot walking robot, hydraulic quadruped robot has attracted much attention due to its high mobility, strong load capacity and smooth motion The electrohydraulic servo cylinder, as its power actuating element, requires low friction ...
SHAO Jun peng, LI Jing bo, SUN Gui tao
doaj   +1 more source

Natural Biomaterials for Osteochondral Repair: From Source to Strategy

open access: yesAdvanced Healthcare Materials, EarlyView.
Biological origin‐guided overview of natural biomaterials and therapeutic strategies for osteochondral tissue engineering. The circular diagram categorizes representative materials and strategies into plant/algae‐derived, microbial‐derived, animal‐derived, and human‐derived sources, centered on an osteochondral defect repair model.
Hengyu Liu   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy