Results 61 to 70 of about 98,203 (376)
Introduction: The Evaluation of Vascular reactivity (VR) is done by the hyperemic response after ischemia produced by arterial occlusion. There are VR measurement techniques that allow the evaluation of vascular function at lower cost and without ...
Diana Carolina Arboleda-Gómez +2 more
doaj +1 more source
Ionic–Bionic Interfaces: Advancing Iontronic Strategies for Bioelectronic Sensing and Therapy
Ionic–bionic interfaces for bioelectronics leverage ions as multifunctional mediators that combine mechanical compliance, ionic and electronic functionalities, and therapeutic effects. These systems offer real‐time biosignal transduction, effective wound dressing, responsive drug delivery, and seamless interaction between soft tissues and electronic ...
Yun Goo Ro +6 more
wiley +1 more source
The acute reduction in peripheral arterial stiffness during reactive hyperemia is assumed to be flow‐mediated; however, the mechanism remains unproven. We hypothesized that restricting the blood flow increase during reactive hyperemia would abolish the ...
Ronald E. Jackson +3 more
doaj +1 more source
Fractional flow reserve versus angiography in guiding management to optimize outcomes in non–ST-elevation myocardial infarction (FAMOUS-NSTEMI): rationale and design of a randomized controlled clinical trial [PDF]
<p>Background: In patients with acute non–ST-elevation myocardial infarction (NSTEMI), coronary arteriography is usually recommended; but visual interpretation of the angiogram is subjective.
Balachandran, Kanarath P. +10 more
core +1 more source
Resorbable impedance sensors are successfully implanted into porcine small intestinal anastomoses. Impedance was recorded for 2 hours prior, and 2 hours following ischemia induction, and a significant drop in tissue impedance was observed. Abstract Anastomotic failure remains one of the most severe complications in gastrointestinal surgery.
Dennis Wahl +12 more
wiley +1 more source
Microvascular dysfunction in the immediate aftermath of chronic total coronary occlusion recanalization [PDF]
Objectives The aim of this study was to compare microvascular resistance under both baseline and hyperemic conditions immediately after percutaneous coronary intervention (PCI) of a chronic total occlusion (CTO) with an unobstructed reference vessel in ...
Alamgir, Farquad +5 more
core +1 more source
This study presents an impedance‐based single‐cell profiling platform that quantifies the electrical and mechanical properties of neutrophils across in vitro, in vivo, and clinical samples. The approach reveals distinct biophysical alterations associated with type 2 diabetes (T2DM) and cardiovascular complications, suggesting its potential utility for ...
Linwei He +13 more
wiley +1 more source
Unaccustomed eccentric exercise leads to impaired microvascular function but the underlying mechanism is unknown. In this study, we evaluated the role of oxidative stress and of nitric oxide (NO) bioavailability.
Ryan G. Larsen +6 more
doaj +1 more source
Episcleral Venous Pressure and the Ocular Hypotensive Effects of Topical and Intracameral Prostaglandin Analogs. [PDF]
There is a limit beyond which increasing either the concentration of a prostaglandin analog (PGA) or its dosing frequency fails to produce increases in ocular hypotensive efficacy with topical dosing.
Alm +36 more
core +2 more sources
Is heart rate response a reliable marker of adenosine-induced coronary hyperemia?
Introduction Growing evidence supports ischemia-guided management of chest pain, with invasive and non-invasive tests reliant upon achieving adenosine-induced coronary hyperemia (defined as increased blood flow to an organ’s perfusion bed).
B. Modi +6 more
semanticscholar +1 more source

