Results 21 to 30 of about 1,162,210 (310)
Comparison of sp-ICP-MS and MDG-ICP-MS for the determination of particle number concentration [PDF]
Analytical and Bioanalytical Chemistry, 407 (14)
Gschwind, Sabrina +2 more
openaire +4 more sources
There are many publications on the quantification of cadmium (Cd) in cocoa beans and cocoa products. However, quantifying Cd in cocoa almonds from beans involves a critical step in the sample preparation process, such as dehulling the beans. This process
Yeni Rodríguez Giraldo +4 more
doaj +1 more source
Elemental bio-imaging using laser ablation-triple quadrupole-ICP-MS
Elemental bio-imaging using the technological advances of ICP-QQQ-MS.
DP Bishop (14539736) +8 more
core +2 more sources
Due to the development of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) around 25 years ago, the isotopes of a large range of elements (masses from Li to U) are now analyzed with high enough precision and accuracy to resolve ...
Nicolas Greber, Kirsten van Zuilen
doaj +1 more source
The application of ordinary least squares (OLS) linear regression is widely used in order to approximate linear external calibration data. However, the assumption of homoscedasticity is often not considered as a requirement for correct data approximation,
Michael Sperling (608490) +5 more
core +1 more source
Boron has gained significant attention in medical research due to its B-10 isotope’s high cross section for the reaction with thermal neutrons, generating ionizing particles that can eliminate cancer cells, propelling the development of boron neutron ...
Emilia Balcer +5 more
doaj +1 more source
Determination of trace metals in electrolytic copper by ICP OES and ICP-MS
The performance of axial view ICP OES and ICP-MS techniques were compared through the determination of As, Fe, Mn, Pb, Sb and Sn in electrolytic copper. Samples were prepared by two procedures: 1. Total dissolution with 5 % v/v HNO3 and 2.
Éder José dos Santos +4 more
doaj +1 more source
Increased demand for monitoring and identification of novel and unknown fluorinated compounds (FCs) has demonstrated the need of sensitive fluorine-specific detectors for unknown FCs in both biological and environmental matrices.
Ruth Lorivi Moirana +4 more
doaj +1 more source
Since its inception in 1980, inductively coupled plasma-mass spectrometry (ICP-MS) has developed as the core technology for trace element analysis in modern analytical chemistry.
Xiu HUANG +7 more
doaj +1 more source
Online preconcentration ICP-MS analysis of rare earth elements in seawater
The rare earth elements (REEs) with their systematically varying properties are powerful tracers of continental inputs, particle scavenging intensity and the oxidation state of seawater.
Stichel, Torben +5 more
core +1 more source