Results 251 to 260 of about 88,261 (305)
Microwave-assisted synthesis of highly photoluminescent core/shell CuInZnSe/ZnS quantum dots as photovoltaic absorbers. [PDF]
Shishodia S +7 more
europepmc +1 more source
Chemodynamic covalent adaptable network-induced robust, self-healing, and degradable fluorescent elastomers for multicolor information encryption. [PDF]
Li C, Su X, Cao C, Li X, Zou M.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
ICP-OES Analysis for Humic Substance
Russian Agricultural Sciences, 2023The possibilities of optical emission spectrometry with inductively coupled plasma (OES-ICP analysis) (in radial plasma observation) of humic preparations (HP) are evaluated, the proposed technique allows quantifying up to 24 elements (As, Al, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Si, S, Sr, Ti, V and Zn).
openaire +1 more source
Comparisons between LIBS and ICP/OES
Analytical and Bioanalytical Chemistry, 2006In the framework of the development of new techniques, the ability of laser-induced breakdown spectroscopy (LIBS) to analyse remotely complex aqueous solutions was investigated. The jet configuration with a collimated gas stream was chosen because it appeared to be the most promising method for the LIBS probe, particularly in terms of sensitivity and ...
P, Fichet +3 more
openaire +2 more sources
Solid-state detector for ICP-OES
Analytical Chemistry, 1993A new type of solid-state detector has been designed to meet the needs of inductively coupled plasma optical emission spectroscopy (ICP-OES), including high quantum efficiency in the UV, low noise, wide dynamic range, rapid readout, broad spectral coverage, and high spectral resolution.
Thomas W. Barnard +6 more
openaire +1 more source
Germanium speciation by LC-HG-ICP/OES
Fresenius' Journal of Analytical Chemistry, 1995Liquid chromatography-hydride generation-inductively coupled plasma optical emission spectroscopy (LC-HG-ICP/OES) has been used to determine inorganic and organometallic species of germanium. In recent studies these coupled systems has been applied successfully to the speciation of arsenic.
A. Padr�, R. Rubio, G. Rauret
openaire +1 more source
Determination of Thorium by ICP-MS and ICP-OES
Radiation Protection Dosimetry, 2001Natural thorium (232-Th) has traditionally been measured by radiometric techniques such as alpha and gamma spectrometry. However. with both ICP-OES and ICP-MS instruments becoming relatively common in many analytical laboratories. these techniques have become more acceptable in thorium analysis.
openaire +2 more sources
Trace Element Determination Using ICP-OES
2022Inductively coupled plasma-optical emission spectroscopy coupled with the benefits of solution chemistry serves as an excellent tool in trace element analysis (TEA) because of its multielement capability, large dynamic range of four to six orders of magnitude, and very high temperature in the range of 7000–10 000 K resulting in virtually complete ...
openaire +1 more source
Multisignal calibration in spark- and ICP-OES
Fresenius' Journal of Analytical Chemistry, 1994The advantages of multivariate calibration by using more than one selective emission line for one analyte are described in comparison with univariate calibration. Principle component regression (PCR) and partial least squares regression (PLS) are compared with classical univariate linear regression of single lines.
Klaus Danzer, Katrin Venth
openaire +1 more source

