Results 71 to 80 of about 4,460,967 (133)

Quantifying variation in DLP‐ to‐ effective‐dose conversion factors in CT using a Monte Carlo‐based dose‐estimation software

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 9, September 2026.
Abstract Background A common method to estimate the effective dose in CT is to multiply the dose length product in a CT scan by a conversion factor (k). The k‐factors are determined by dividing the effective dose (calculated using a weighted summation of organ doses) by the dose length product (DLP) for specific digital phantoms.
Jelena M. Mihailovic   +5 more
wiley   +1 more source

Radiation‐Induced Cutaneous Tissue Reactions in Neurointerventional Procedures: A Systematic Review of Reported Effects and Associated Dose Levels

open access: yesJournal of Medical Imaging and Radiation Oncology, Volume 70, Issue 6, Page 561-572, September 2026.
ABSTRACT Neurointerventional procedures can deliver high localised skin doses and may cause radiation‐induced cutaneous tissue reactions, yet the doses at which these occur have not been synthesised specifically for this setting. We systematically reviewed reported cutaneous reactions and associated radiation doses after fluoroscopy‐ or digital ...
Mohamed Khaldoun Badawy   +5 more
wiley   +1 more source

Folder 9: Model engine data sheets and operating instructions, P - S, 1942, 1990, 1998

open access: yes, 1942
Operating instructions and illustration for the Phantom Bullet model engine.
Phantom Motors
core   +1 more source

Systematic review of physical and dosimetric criteria for managing CIEDs in radiotherapy: A medical physicist's perspective

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Aim Current radiotherapy (RT) guidelines for Cardiac Implantable Electronic Devices (CIEDs) are largely based on clinical management strategies and retrospective reports. This systematic review adopts a medical physics perspective to provide a critical, quantitative analysis of the technical evidence required for developing robust safety ...
Tiziana Malatesta   +15 more
wiley   +1 more source

Organ Dose Calculations Using ICRP Adult Voxel Phantoms and TRIPOLI-4 Monte Carlo Code

open access: yes, 2020
International audienceAbstract The ICRP 110 adult male and female voxel phantoms are the official computational models representing the ICRP (International Commission on Radiological Protection) Reference Male and Reference Female.
Lee, Yi-Kang, Yi-Kang Lee
core   +1 more source

Analysis of TG-43 dosimetric parameters for an Ir-192 HDR brachytherapy source using with the Geant4 toolkit

open access: yesBrazilian Journal of Radiation Sciences
This study evaluated the dosimetric parameters of the Buchler G089 192Ir high-dose-rate brachytherapy source using the TG-43 formalism and Monte Carlo simulations with the Geant4 toolkit. The radial dose function and the anisotropy function were obtained
Alice Albuquerque   +2 more
doaj   +1 more source

The ICRP recommended methods of red bone marrow dosimetry.

open access: yes, 2021
To account for an enhancement of the absorbed dose to both active marrow and endosteum due to secondary electrons generated in bone trabeculae and depositing energy in adjacent marrow tissues, a specific method for bone dosimetry has been developed and ...
Gómez Ros, José-María   +11 more
core   +1 more source

Simulation-based estimation of dosimetric quantities for different phantom compositions and the effectiveness of aluminum shielding against galactic cosmic rays

open access: yesRadiation Protection and Environment
Astronauts on space missions are exposed to high radiation levels, especially from galactic cosmic rays (GCRs), which consist of particles with high energy such as protons, helium ions, and heavy ions.
Rohit Yadav   +3 more
doaj   +1 more source

Computational phantoms, ICRP/ICRU and further developments.

open access: yes, 2017
Phantoms simulating the human body play a central role in radiation dosimetry. The first computational body phantoms have been based upon mathematical expressions describing idealised body organs.
Bolch, W.E.   +5 more
core  

Different effective dose conversion coefficients for monoenergetic neutron fluence from 10-9 MeV to 20 MeV – A methodological comparative study

open access: yes, 2012
Calculations are presented of the effective doses per unit neutron fluence according to the ICRP publications 60 and 103. Monte Carlo N-Particle (MCNPX) code was used for six geometrical conditions of irradiation (Anterior-Posterior, Posterior-Anterior ...
H. Miri H., K. Karimi S., L. Rafat M.
core   +1 more source

Home - About - Disclaimer - Privacy