Effects of Organic Acidic Products from Discharge-Induced Decomposition of the FRP Matrix on ECR Glass Fibers in Composite Insulators. [PDF]
Zhang D, Wan Z, Shi K, Lu M, Gao C.
europepmc +1 more source
Partial Discharge Fault Diagnosis in Power Transformers Based on SGMD Approximate Entropy and Optimized BILSTM. [PDF]
Shang H, Zhao Z, Li J, Wang Z.
europepmc +1 more source
Wavelet-based arcing signal source localization algorithm using a compact multi-square microstrip antenna. [PDF]
Amirruddin M +6 more
europepmc +1 more source
Application of Pathfinding Algorithms in Partial Discharge Localization in Power Transformers. [PDF]
Beura CP, Wolters J, Tenbohlen S.
europepmc +1 more source
Related searches:
Fundamental differences of the PD measurement according to IEC 60270 and in UHF range
2008 International Conference on Condition Monitoring and Diagnosis, 2008PD measurements in the UHF frequency range are an important tool for diagnostic at GIS. A general correlation between the measurement according to IEC standard 60270 and measurements in the UHF range is not possible. By the use of a ldquosensitivity checkrdquo the quality of the UHF measuring system is verified at GIS.
S.M. Hoek +3 more
openaire +1 more source
Comparative study of IEC 60270 compliant instruments for partial discharge pattern acquisition
2016 Petroleum and Chemical Industry Technical Conference (PCIC), 2016The petrochemical industry considers offline partial discharge (PD) measurement an important quality assessment for new medium voltage motor and generator stator windings. A recent edition of API 541 requires an instrument compliant with IEC 60270 for the measurement of PD on sacrificial stator coils, and proposes 100 pC (pico-Coulombs) for guidance on
Saeed Ul Haq +2 more
openaire +1 more source
Comparison of Sensitivity Between UHF Method and IEC 60270 for Onsite Calibration in Various GIS
IEEE Transactions on Power Delivery, 2006It is more important to obtain the sensitivity line, which is defined as a correlation between the ultra-high-frequency (UHF) signal (mV) and apparent charge (pC), for onsite calibration regarding partial discharge (PD). Synchronous measurement of the UHF method and IEC 60270 enables us to obtain the sensitivity line and to estimate the apparent charge
T. Hoshino +3 more
openaire +1 more source
Measuring partial discharge according to IEC60270 is a well established and widely accepted method. Unfortunately it presents some limitations especially when it is necessary to monitor the system under load conditions and when the localization of the discharge sources is demanded. To overcome these problems, other techniques have been developed in the
Giussani, R. +2 more
openaire +1 more source
What can go wrong during stator coil partial discharge measurements according to IEC 60270?
2014 Petroleum and Chemical Industry Conference Europe, 2014The available literature on partial discharge (PD) analysis suggests that measurements should be performed at higher frequency bandwidth than the conventional IEC 60270 methods, to enhance capability for detection of stator coil defects. In an energized test object, electrical disturbances or noise can strongly influence the observed PD magnitude ...
Saeed Ul Haq +3 more
openaire +1 more source