Results 1 to 10 of about 69,448 (250)
Vulnerability and Impact Analysis of the IEC 61850 GOOSE Protocol in the Smart Grid [PDF]
IEC 61850 is one of the most prominent communication standards adopted by the smart grid community due to its high scalability, multi-vendor interoperability, and support for several input/output devices. Generic Object-Oriented Substation Events (GOOSE),
Haftu Tasew Reda +6 more
doaj +3 more sources
As micro grids are gradually being deployed in many areas, communication technology is becoming important for collecting data and controlling devices in micro grids. In a micro grid, various devices are distributed and perform their respective functions.
Hyun-Ji Jun, Hyo-Sik Yang
doaj +2 more sources
Modern power systems require increased connectivity to implement novel coordination and control schemes. Wide-spread use of information technology in smartgrid domain is an outcome of this need. IEC 61850-based communication solutions have become popular
Taha Selim Ustun +3 more
doaj +2 more sources
Integration of IoT Technologies into the Smart Grid [PDF]
This paper presents a novel solution in the field of the integration of the Smart Grid and the Internet of Things. The definition of a web platform able to offer a RESTful interface to IEC 61850 Servers to a generic user is proposed.
Salvatore Cavalieri +2 more
doaj +2 more sources
Towards Latency Bypass and Scalability Maintain in Digital Substation Communication Domain with IEC 62439-3 Based Network Architecture [PDF]
Parallel redundancy protocol (PRP) and high-availability redundancy protocol (HSR) are widely adopted protocols based on IEC 61850 standard to support zero recovery communication networks for time-critical and reliable interactions in power system ...
Lilia Tightiz, Joon Yoo
doaj +2 more sources
Performance evaluation of IEC 61850 MMS messages under cybersecurity considerations
IEC 62351-4 standard is published to address cybersecurity vulnerabilities of IEC 61850 Manufacturing Message Specification (MMS) messages. This standard includes a set of cipher suites that are recommended for securing MMS messages.
Taha Selim Ustun +2 more
doaj +1 more source
A Fixed-Latency Architecture to Secure GOOSE and Sampled Value Messages in Substation Systems
International Electrotechnical Commission (IEC) 62351-6 standard specifies the security mechanisms to protect real-time communications based on IEC 61850. Generic Object Oriented Substation Events (GOOSE) and Sampled Value (SV) messages must be generated,
Mikel Rodriguez +4 more
doaj +1 more source
Implementation of IEC 61850 power protection tester in Linux environment [PDF]
Software power protection tester implemented in a real-time operating system (RTOS) might replace the conventional testing setups in IEC 61850 protection systems. This paper describes an open power protection testing platform.
K. Kurek +3 more
doaj +1 more source
Reactive power management in microgrids with high penetration of distributed renewable energy sources (DRESs) is challenging. The intermittent generation of DRES makes the power management cumbersome.
S. M. Suhail Hussain +2 more
doaj +1 more source
Dynamic operation and control of power system is being increasingly done with the help of phasor measurement unit (PMU) based wide area monitoring and control system.
Ikbal Ali +2 more
doaj +1 more source

