Performance evaluation of IEC 61850 MMS messages under cybersecurity considerations
IEC 62351-4 standard is published to address cybersecurity vulnerabilities of IEC 61850 Manufacturing Message Specification (MMS) messages. This standard includes a set of cipher suites that are recommended for securing MMS messages.
Taha Selim Ustun +2 more
doaj +1 more source
SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid [PDF]
In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude.
Mansi Girdhar +4 more
semanticscholar +1 more source
An Adaptive Overcurrent Protection for Solar-based DC Microgrids Using IEC 61850 [PDF]
Over-Current (OC) protection is one of the pervasive protections in solar-based DC microgrids. Fast operation is a key advantage of its popularity. On the other hand, utilizing OC in DC microgrids has some challenges that are not in AC grids.
Saeed Sanati, M. Azzouz, A. Awad
semanticscholar +1 more source
Digital Substations and IEC 61850: A Primer
Modern electrical substations are managed by intelligent electronic devices communicating through Ethernet-based networks. Because of the highly critical roles of substations, which include safety and protection, electronic devices need to be configured ...
Juan Lozano +3 more
semanticscholar +1 more source
Review of the Legacy and Future of IEC 61850 Protocols Encompassing Substation Automation System
Communication protocols play a pivotal role in the substation automation system as they carry critical information related to asset control, automation, protection, and monitoring.
Shantanu Kumar +3 more
semanticscholar +1 more source
A Fixed-Latency Architecture to Secure GOOSE and Sampled Value Messages in Substation Systems
International Electrotechnical Commission (IEC) 62351-6 standard specifies the security mechanisms to protect real-time communications based on IEC 61850. Generic Object Oriented Substation Events (GOOSE) and Sampled Value (SV) messages must be generated,
Mikel Rodriguez +4 more
doaj +1 more source
An Effective Security Scheme for Attacks on Sample Value Messages in IEC 61850 Automated Substations
The trend of transforming substations into smart automated facilities has led to their swift digitalization and automation. To facilitate data exchange among equipment within these substations, the IEC 61850 standard has become the predominant standard ...
S. M. Suhail Hussain +5 more
semanticscholar +1 more source
Next-Generation Power Substation Communication Networks: IEC 61850 Meets Programmable Networks
The electrical grid is undergoing a fundamental change with the introduction of smart grid technologies. In particular, power substations have been evolving toward more automated systems.
S. Gutiérrez +4 more
semanticscholar +1 more source
Attacking IEC 61850 Substations by Targeting the PTP Protocol
Digital substations, also referred to as modern power grid substations, utilize the IEC 61850 station and process bus in conjunction with IP-based communication.
A. Akbarzadeh +4 more
semanticscholar +1 more source
Reactive power management in microgrids with high penetration of distributed renewable energy sources (DRESs) is challenging. The intermittent generation of DRES makes the power management cumbersome.
S. M. Suhail Hussain +2 more
doaj +1 more source