Results 71 to 80 of about 64,273 (210)

Multi‐point‐line Grounding Fault Section Identification in Urban Distribution Networks by Using Coordinated Multi‐Source Data

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A multi‐source data collaborative fault section identification method for high fault‐tolerant distribution networks is proposed. The method constructs a robust mixed‐integer linear programming cooperative model by integrating zero‐sequence current direction features and fault indicator alarm signals.
Wangqing Mao   +5 more
wiley   +1 more source

Fast bus protection using iec 61850 [PDF]

open access: yes, 2013
International Electrotechnical Commission (IEC) 61850 is the latest technology that allows electric power utilities to build low cost digital substations.
Goff, Cassandra Ha
core   +1 more source

Higher‐Order Statistics Based Pilot Protection Scheme for Wind Farm Transmission Line Connected to VSC Station

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper analyses the distribution of fault current samples for both external and internal faults conditions and quantifies the differences in the features by using the third‐order cumulant and kurtosis. On this basis, a pilot protection scheme was proposed for transmission lines wind farm transmission line connected to VSC station.
Ziliang Wu   +7 more
wiley   +1 more source

Analysis and Implementation of Message Authentication Code (MAC) Algorithms for GOOSE Message Security

open access: yesIEEE Access, 2019
There is growing awareness towards cybersecurity threats in power systems. IEC 61850 standard facilitates communication between different Intelligent Electronic devices (IEDs) and eases interoperable operation with set data and message structures.
S. M. Suhail Hussain   +2 more
doaj   +1 more source

5G for IEC 61850 Smart Grid Communications: Mapping Technology Enablers and Network Slicing Performance Insights

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper maps key 5G technology enablers, such as carrier aggregation, dual connectivity, and network slicing (NS), to IEC 61850 smart grid communication traffic types and experimentally evaluates their performance in commercial 5G networks. Results show that NS enhances reliability for grid protection and automation but still falls short of ultra ...
Petra Raussi   +5 more
wiley   +1 more source

Detecting False Data Injection in Smart Grid Overcurrent Relay Settings Using an AE–GAN–SVM Framework

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This paper introduces a novel protection‐aware AE–GAN–SVM hybrid framework designed to detect and mitigate coordinated false data injection attacks targeting PMU and relay‐setting domains. By integrating topology‐aware generative modelling with swarm robotics search and rescue (SRSR) optimisation, the framework enhances reliability and cyber‐physical ...
Mohammad Bakhshipour   +2 more
wiley   +1 more source

Sähköaseman IEC 61850-prosessiverkko [PDF]

open access: yes, 2019
Opinnäytetyön tarkoitus oli tutkia IEC 61850-prosessiverkon standardeja ja toimintatapoja ja selvittää kuinka yritykset voivat valmistautua tulevaan tekniikkaan.
Mölsä, Marko
core  

Mitigating Grid Stability Risks From Large AI Data Centres: A Three‐Mode Supervisory Control Framework for Centralized UPS Systems

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
A three‐mode supervisory control framework for centralized data centre UPS systems mitigates the grid stability risks posed by large AI facilities during transmission faults. The framework coordinates current‐limited reactive‐priority allocation, a minimum‐draw policy to limit aggregate load withdrawal and rate‐limited post‐fault recovery, extended to ...
Mohamed Shamseldein
wiley   +1 more source

IEC 61850-elstation i COM600 [PDF]

open access: yes, 2017
Detta examensarbete behandlar konfiguration och övervakning av en simulerad elstation. I DEMVE-labbet vid Technobothnia i Vasa undersöks och testas IEC 61850-kommunikation från skyddsreläer av olika tillverkare.
Nyman, Mikael
core  

Home - About - Disclaimer - Privacy