IEC 62351-4 Security Implementations for IEC 61850 MMS Messages
With the deployment of advanced information and communication technologies (ICT) the legacy power grid is being transformed as smart grid. However, the extensive use of ICT makes it vulnerable to cyberattacks.
Taha Selim Ustun, S. M. Suhail Hussain
doaj +3 more sources
A Review of IEC 62351 Security Mechanisms for IEC 61850 Message Exchanges [PDF]
Smart grid is the nexus of advanced information and communication technologies and legacy power systems. With increasing awareness on the vulnerabilities of smart grids to cyberattacks, cybersecurity is becoming a prime concern. Earlier, it was assumed that the power system communication protocols are very specialized and different, so the “security by
S. M. Suhail Hussain +2 more
openaire +3 more sources
A Fixed-Latency Architecture to Secure GOOSE and Sampled Value Messages in Substation Systems [PDF]
International Electrotechnical Commission (IEC) 62351-6 standard specifies the security mechanisms to protect real-time communications based on IEC 61850. Generic Object Oriented Substation Events (GOOSE) and Sampled Value (SV) messages must be generated,
Mikel Rodriguez +4 more
doaj +3 more sources
Performance evaluation of IEC 61850 MMS messages under cybersecurity considerations [PDF]
IEC 62351-4 standard is published to address cybersecurity vulnerabilities of IEC 61850 Manufacturing Message Specification (MMS) messages. This standard includes a set of cipher suites that are recommended for securing MMS messages.
Taha Selim Ustun +2 more
doaj +3 more sources
A novel hybrid methodology to secure GOOSE messages against cyberattacks in smart grids. [PDF]
: IEC 61850 is emerging as a popular communication standard for smart grids. Standardized communication in smart grids has an unwanted consequence of higher vulnerability to cyber-attacks. Attackers exploit the standardized semantics of the communication
Hussain S +7 more
europepmc +4 more sources
S-GoSV: Framework for Generating Secure IEC 61850 GOOSE and Sample Value Messages [PDF]
Standardized communication plays an important role in substation automation system (SAS). IEC 61850 is a de-facto standard in SAS. It facilitates smooth communication between different devices located in the substation by achieving interoperability ...
Shaik Mullapathi Farooq +2 more
doaj +3 more sources
A Symmetric Encryption Method for Transmitting IEC 62351 Communicaiton Keys in Substations
With the improvement of the information level of the substation, the cyber security problem of information communication has become increasingly prominent.
Fang FANG +3 more
doaj +2 more sources
EFICIÊNCIA COM SEGURANÇA: INTEGRAÇÃO DO IEC 61850 COM O IEC 62351 PARA MITIGAR RISCOS DE ATAQUES CIBERNÉTICOS EM SUBESTAÇÕES DIGITAIS [PDF]
A automação de subestações elétricas desempenha um papel crítico na modernização e eficiência dos sistemas de energia elétrica. No entanto, a crescente dependência do protocolo IEC 61850 para comunicação e controle pode criar vulnerabilidades significativas à segurança cibernética.
Pacheco, Lucas Matheus Matos +6 more
openaire +3 more sources
Application of role-based access control in cyber security of substation
By following the encrypted communication proposed by IEC 62351-3 and the identity authentication technology by IEC 62351-4, the paper carries out research on role-based access control technology on the theoretical basis of IEC 62351-8.
RUAN Lixiang +3 more
doaj +1 more source
Protection of Energy Network Infrastructures Applying a Dynamic Topology Virtualization
Rapid progress of computing and info-communication technologies (ICT) has changed the ecosystem of power production and delivery. Today, an energy network is a complex set of interrelated devices and information systems covering all areas of electric ...
Maxim Kalinin +2 more
doaj +1 more source

