Integration of a surgical robotic arm to the connected operating room via ISO IEEE 11073 SDC. [PDF]

open access: hybridInt J Comput Assist Radiol Surg, 2023
Purpose Since 2019, intraoperative networking with ISO IEEE 11073 SDC has, for the first time, enabled standardized multi-vendor data exchange between medical devices.
Wickel N   +4 more
europepmc   +4 more sources

Silent ICU based on IEEE 11073 SDC [PDF]

open access: goldCurrent Directions in Biomedical Engineering, 2023
Patients and caregivers suffer from alarm-related noise in today’s hospitals. While this is a topic for all fields of care, this challenge is especially relevant for intensive care units (ICUs).
Kasparick Martin   +7 more
doaj   +3 more sources

A practical example of an integrated interoperable neuromonitoring system based on IEEE 11073 SDC and HL7 [PDF]

open access: goldCurrent Directions in Biomedical Engineering, 2023
Purpose: With the ongoing work on the Health Level Seven (HL7) standards and the IEEE 11073 Serviceoriented Device Connectivity (SDC) family, the demand for open integration of medical devices in the operating room (OR) has become clear.
Weßbecher Lea   +4 more
doaj   +3 more sources

Consideration of the generated network utilization of the IEEE 11073 SDC standard [PDF]

open access: goldCurrent Directions in Biomedical Engineering, 2022
This paper investigates the extent to which the IEEE 11073 SDC standard family loads a communication network. An SDC provider/consumer based on the SDCLib/J from SurgiTAIX AG was implemented as a test environment and several different test scenarios were
Thürk Gregor   +3 more
doaj   +3 more sources

IEEE 11073 SDC for Pandemics like COVID-19: Example Implementation of an Isolation Room [PDF]

open access: goldCurrent Directions in Biomedical Engineering, 2022
Treating patients in an intensive care unit (ICU) isolation room is full of challenges for the caregivers and the patients. While this is known for years, the COVID-19 pandemic has highlighted these challenges as if under a burning glass - intensified by
Kasparick Martin   +8 more
doaj   +3 more sources

Evaluation of an IEEE 11073 SDC Connection of two KUKA Robots towards the Application of Focused Ultrasound in Radiation Therapy [PDF]

open access: goldCurrent Directions in Biomedical Engineering, 2019
The integration of surgical robotics into the operating room requires reliable and flexible communication with other medical devices. The IEEE 11073 SDC standard can provide the necessary requirements to deploy robotics for the application of focused ...
Berger Johann   +3 more
doaj   +3 more sources

Design and validation of a medical robotic device system to control two collaborative robots for ultrasound-guided needle insertions [PDF]

open access: yesFrontiers in Robotics and AI, 2022
The percutaneous biopsy is a critical intervention for diagnosis and staging in cancer therapy. Robotic systems can improve the efficiency and outcome of such procedures while alleviating stress for physicians and patients.
Johann Berger   +6 more
doaj   +3 more sources

Service-Oriented Medical Device Connectivity: Particular Interoperability Standards for High Frequency Surgical Equipment and External Control Devices

open access: yesCurrent Directions in Biomedical Engineering, 2021
Manufacturer-independent medical device interoperability has been strongly demanded by the clinicians and healthcare delivery organizations (HDOs), however has not been achieved in practice for decades.
Kasparick Martin   +11 more
doaj   +2 more sources

Concept and development of a telemedical supervision system for anesthesiology in operating rooms using the interoperable communication standard ISO/IEEE 11073 SDC [PDF]

open access: closedBiomedizinische Technik. Biomedical engineering
Objectives Discussion of a telemedical supervision system for anesthesiology in the operating room using the interoperable communication protocol SDC. Validation of a first conceptual demonstrator and highlight of strengths and weaknesses.
Jonas Roth   +6 more
openalex   +2 more sources

Integration of Robotic Applications in Open and Safe Medical Device IT Networks Using IEEE 11073 SDC

open access: bronze, 2018
Modern operating rooms (OR) undergo a constant rise in the amount and complexity of technical systems. Due to a lack of inter-device communication and integration, each device works stand-alone resulting in redundant sensors, input devices, monitors and ...
Manuel Vossel   +6 more
openalex   +3 more sources