This article describes brachial access to position a long sheath in the abdominal aorta in conjunction with a large caliber sheath via the femoral artery ipsilateral to the target site to deliver a 0.018 bodyfloss wire.
S. Keisin Wang, MD +5 more
doaj +2 more sources
Midterm result of custom-made iliac branch device for common iliac aneurysm with and without abdominal aortic aneurysm. [PDF]
Huang CY +7 more
europepmc +2 more sources
Comments on Clinical and Haemodynamic Evaluation of a Novel Physician Modified Inner Branch Iliac Branch Device for East Asians [PDF]
Mingwei Wu, Jingqi Shen, Jiang Xiong
doaj +2 more sources
Endovascular repair using iliac branch devices for small-diameter abdominal aortic dissection aneurysm with proximal stenosis: a case report [PDF]
Background Abdominal aortic dissection aneurysm (AADA) with severe proximal stenosis often fails to meet the anatomical criteria for standard endovascular aneurysm repair (EVAR).
Yukang Chen, Zuoyi Yao
doaj +2 more sources
Late chronic total occlusion of infrarenal aortic stent graft and iliac branch device presenting as chronic limb-threatening ischemia [PDF]
Kazumasa Hanada, MD, PhD +1 more
doaj +2 more sources
Use of Iliac Branch Device for Endovascular Treatment for Abdominal Aorta Aneurysm with Small Diameter Neck. [PDF]
We present the case of a 78-year-old woman with a 4.5-cm symptomatic abdominal aortic aneurysm with a small diameter (13-mm diameter) infrarenal aortic neck who underwent endovascular treatment using an iliac branch device as a bifurcated aortic stent ...
Rossi UG +3 more
europepmc +2 more sources
Efficacy and safety of Jotec E-ventus BX stent graft for iliac branch device procedure. A retrospective clinical study [PDF]
The endovascular aneurysm repair (EVAR) is a successful treatment for aorto-iliac aneurysms. The success of EVAR is enhanced by the use of devices that maintain the patency of targeted arteries namely the iliac branch device (IBD) With this study we ...
Turchino, Davide +27 more
core +1 more source
Iliac Branch Devices in Women: Results From the pELVIS Registry [PDF]
Iliac Branch Devices in Women: Results From the pELVIS Registry Iliac branch device (IBD) technology has become a more accepted endovascular option to preserve internal iliac ar- tery flow for aneurysms involving the iliac bifurcation. Because several studies reported inferior outcomes in women compared with men after endovascular aortic aneurysm ...
Soler R. +26 more
openaire +2 more sources
Endovascular treatment with iliac branch devices: multicenter study [PDF]
Introduction: it is estimated that between 18 39 % of patients with aorto-iliac aneurysms undergoing endovascular treatment have a no suitable zone for distal sealing in common iliac arteries. Traditionally, one of the options is to perform distal seal at the external iliac arteries occluding the hypogastric arteries.
Granja, JIC +7 more
openaire +3 more sources
Iliac Branch Devices in the Repair of Ruptured Aorto-iliac Aneurysms: A Multicenter Study
Purpose: To evaluate the outcomes of preserving the internal iliac artery (IIA) with iliac branched devices (IBDs) during acute endovascular repair of ruptured aortoiliac aneurysms. Material and Methods: This is a multicenter ...
Angelos Karelis +12 more
openaire +5 more sources