Results 121 to 130 of about 9,580,614 (228)

Valoración densitométrica de la osteogénesis en distracción: estudio experimental [PDF]

open access: yes, 1991
Comprobamos experimentalmente la utilidad de la densitometrí a ósea en el seguimiento evolutivo de la osteogénesis en distracción. Se utilizaron 12 corderos de 2 meses de edad, en los que se practicó a nivel del fémur izquierdo, un a osteotomía ...
Cañadell Carafí, José   +2 more
core  

Tensile Stress‐Activated and Exosome‐Transferred YAP/TAZ‐Notch Circuit Specifies Type H Endothelial Cell for Segmental Bone Regeneration

open access: yesAdvanced Science
The Ilizarov technique has been continuously innovated to utilize tensile stress (TS) for inducing a bone development‐like regenerative process, aiming to achieve skeletal elongation and reconstruction.
Feng Wang   +11 more
doaj   +1 more source

Relationship between radiologic morphology of the bone lengthening formation and its complications [PDF]

open access: yes, 1992
The objective was to study the different types of lengthened bone regeneration and their development during the various phases of the process to correlate them with patient factors and the surgical technique used, and to establish a ...
Aquerreta, D. (Dámaso)   +4 more
core  

Application of monorail fixator for femoral gap nonunion

open access: yesChinese Journal of Traumatology, 2014
【Abstract】Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously.
Agrawal Hemendra Kumar   +3 more
doaj  

Utilización de fijadores externos circulares en el tratamiento de la pseudoartrosis infectada de tibia secuela de aplastamiento de miembros [PDF]

open access: yes, 1996
Se revisan 7 casos de pseudoartrosis infectada de tibia, secuela de aplastamiento de miembros, tratadas inicialmente en el momento de la fractura con desbridamiento y fijador externo monolateral.
Blasco Molla, G.   +2 more
core  

Ilizarov fixator versus plates and screws for treatment of high-energy tibial plateau fractures

open access: yesSVU - International Journal of Medical Sciences
Background: Bicondylar tibial plateau fractures stand as severe injuries that need surgical intervention. They are often linked to elevated complication rates as well as suboptimal clinical outcomes. Objectives: To compare ilizarov external fixation and
Mohamed Nasr Gafar Ahmed *   +2 more
doaj   +1 more source

Lower Leg Deformity Correction Using Ilizarov Device in Dr Soetomo General Hospital Surabaya: a Case Series [PDF]

open access: yes, 2018
Background: limb deformity, especially lower leg deformity is a common case in orthopaedic practice. Limb deformity can be classified according to cause (Congenital, developmental, post trauma), geometry (angulation, rotation, shortening), severity and ...
Andrianus, J. (Jeffry)   +1 more
core  

Large Experimental Segmental Bone Defects Treated By Bone Transportation With Monolateral External Distractors [PDF]

open access: yes, 1994
Monolateral frames were applied to five dogs and ten lambs for treatment of large segmental bone defects (LSBD) surgically induced in one of their femoral diaphyses. Reconstruction was attempted by bone transport, as developed by Ilizarov.
Alfaro, C. (Carmen)   +3 more
core  

Infected Tibial Nonunion: assessment of Compression distraction Ilizarov technique without debridement.

open access: yesOrthopaedics & Traumatology: Surgery & Research, 2021
M. Meselhy   +3 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy