Is it mandatory to routinely use image intensifier during scoliosis surgery? – Results of an email survey [PDF]
Background: It is now considered standard of care to use Spinal cord monitoring during scoliosis surgery. Use of Image intensifier during scoliosis surgery, on the other hand, is highly variable in United Kingdom (UK) spine centres.
Devi Prakash Tokala, Sashin Ahuja
doaj +2 more sources
Effectiveness of Flat-Panel Fluoroscopy in Direct Anterior Total Hip Arthroplasty: A Comparison to Image Intensifier Fluoroscopy With Radiopaque Grid [PDF]
Introduction: The use of traditional, image intensifier fluoroscopy with a radiopaque grid during direct anterior total hip arthroplasty (DA THA) has demonstrated reduced variability in component positioning and operative time compared to fluoroscopy ...
Zachary A. Gapinski, MD +3 more
doaj +2 more sources
Characteristic Evaluation of an Intensifier Detector for SMILE UVI [PDF]
As one of the payloads on board the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) spacecraft, the ultraviolet imager (UVI) aims to capture N2 Lyman–Birge–Hopfield (LBH) aurora continuously on a high-eccentricity orbit.
Yongmei Wang +10 more
doaj +2 more sources
Real-time intraoperative 3D image intensifier-based navigation in reversed shoulder arthroplasty- analyses of image quality [PDF]
Background Due to the high anatomical variability and limited visualization of the scapula, optimal screw placement for baseplate anchorage in reversed total shoulder arthroplasty (rTSA) is challenging.
Jan Theopold +4 more
doaj +2 more sources
Avoiding Complications and Technical Variability During Arthroscopically Assisted Transtibial ACL Reconstructions by Using a C-Arm With Image Intensifier [PDF]
Background: Surgical reconstruction of the anterior cruciate ligament (ACL) can be complicated by incorrect and variable tunnel placement, graft tunnel mismatch, cortical breaches, and inadequate fixation due to screw divergence. This is the first report
Natasha Trentacosta MD +4 more
doaj +2 more sources
A practical technique for optimal visualization of popliteal artery in patients with prior knee arthroplasty [PDF]
A practical technique to visualize popliteal artery in patients with prior knee arthroplasty is described using ipsilateral lateral knee flexion and contralateral oblique position of the image intensifier. This position is well-tolerated without any risk
Sachinder Singh Hans, MD
doaj +2 more sources
Development and Testing of a Novel Microstrip Photocathode ICCD for Lunar Remote Raman Detection [PDF]
The intensified charge-coupled device (ICCD), known for its exceptional low-light detection performance and time-gating capability, has been widely applied in remote Raman spectroscopy systems.
Haiting Zhao +10 more
doaj +2 more sources
Flat panel detector (FPD) technology in interventional cardiology is on the increase due to its varied advantages compared to the conventional image intensifier (II) systems.
Roshan S Livingstone +4 more
doaj +2 more sources
Image Intensifier guided repositioning of a malpositioned internal jugular vein introducer sheath [PDF]
Saurabh Khurana +2 more
doaj +2 more sources
An Ultrasound-Assisted Technique to Fix the Avulsion Fracture of the Posterior Tibial Spine
Background: The fixation of posterior tibial avulsion fractures has been predominantly open reduction and internal fixation that leads to longer incision, severe scarring and higher risk to neurovascular injury while using the posterior approach.
Gautam Kumar +4 more
doaj +1 more source