Results 51 to 60 of about 22,522 (259)
Immersion Cooling of Electronics in DoD Installations: [PDF]
A considerable amount of energy is consumed to cool electronic equipment in data centers. A method for substantially reducing the energy needed for this cooling was demonstrated. The method involves immersing electronic equipment in a non-conductive liquid that changes phase from a liquid to a gas. The liquid used was 3M Novec 649.
Coles, Henry, Herrlin, Magnus
openaire +1 more source
Four‐point bending tests are conducted in an argon atmosphere on commercial MgO‐C brick grades with and without MgO‐C recyclate from room temperature up to 1300 °C. No detrimental effect of the MgO‐C recyclates on bending strength is found. Instead, a decisive influence of the total carbon content is observed, with lower total carbon contents ...
Alexander Schramm +5 more
wiley +1 more source
Thermal Management Innovations for Energy-Efficient A.I. Data Centres [PDF]
This Paper examines innovative thermal management strategies to improve the energy efficiency of AI data centres. Data centres currently consume about 415 TWh of electricity annually, roughly 1.5% of global demand, with projections reaching 945 TWh by ...
ikenna Ekpe +5 more
doaj +1 more source
This study investigates thermo‐chemical processes during high‐temperature testing of two commercial MgO‐C brick grades, one containing 47.5 wt.% MgO‐C recyclate. Using ETV, DTA/TG‐MS, XRD, and SEM/EDS/EBSD, mechanisms such as carbothermal reduction of magnesia, impurity incorporation into the secondary MgO surface layer, and calcium‐rich phase ...
Alexander Schramm +6 more
wiley +1 more source
To meet the growing thermal management needs of data centers, immersion phase change cooling technology is adopted. This project established a performance model of an immersion phase-change cooling system and simulated the performance of four coolants in
Wu Xilei +6 more
doaj
Thermophysical Properties of the Desulphurization Slags With Various CaS and CaO/Al2O3 Ratio
This article investigates how CaS content and the CaO/Al2O3 ratio influence the thermophysical properties of desulphurization slags. Using experimental measurements and thermodynamic simulations, this study reveals complex effects on viscosity, surface tension, and density, providing new insight into slag structure and phase behavior under ...
Eldar Salpagarov +4 more
wiley +1 more source
Thermal Management of Li-Ion Batteries With Single-Phase Liquid Immersion Cooling
Development of effective thermal management techniques is essential in enabling further technical advances and wide public acceptance of lithium-ion based battery electrical storage.
David W. Sundin, Sebastian Sponholtz
doaj +1 more source
Carbon‐free inert anodes are essential for decarbonizing aluminum electrolysis. This study investigates a recyclate‐based MgO‐316L steel composite anode tested under galvanostatic Hall–Héroult conditions in cryolite at 1000°C. Microstructural analysis reveals selective MgO fluorination, spinel and oxide layer formation, electrolyte infiltration, and ...
Serhii Yaroshevskyi +7 more
wiley +1 more source
Removing Oxide Layers and Retaining Oxide‐Free Steel Surfaces by Polishing in Oxygen‐Free Atmosphere
In this study, the efficacy of wet mechanical polishing under an oxygen‐free atmosphere for deoxidation and the retention of an oxide‐free steel surface are elucidated using X‐ray photoelectron spectroscopy. The methodology proved successful; however, the results were highly dependent on the preparation of the solvents used to clean the samples after ...
Friedrich Bürger +2 more
wiley +1 more source
The formation of nonmetallic inclusions (NMIs) was investigated in this study, carrying out immersion tests for 30 min at a temperature of 1600°C with liquid high‐silicon electrical steel (Si ≈ 3 mass‐%) and different MgO–C refractories. Conventional MgO–C refractories were considered, as well as MgO–C refractories containing MgO–C recyclate and ...
Lukas Neubert +6 more
wiley +1 more source