Results 241 to 250 of about 543,974 (301)

Textile Pattern-Reconfigurable Antennas for 2.45 GHz Off-Body and On-Body Communications. [PDF]

open access: yesMicromachines (Basel)
Cui J   +6 more
europepmc   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Effect of External Source Impedance on the Input Impedance of Digital Impedance Circuits

2020 IEEE International Symposium on Circuits and Systems (ISCAS), 2020
The input impedance of recently-introduced digital impedance circuits has been discovered to be dependent on the impedance of the external signal source. To address this problem, the theory for the dependence of digital impedance on external source resistance is presented.
Kristy A. Hecht   +2 more
openaire   +2 more sources

Faradaic Impedances: Diffusion Impedance and Reaction Impedance

Journal of The Electrochemical Society, 1970
Relative contributions of double‐layer and faradaic impedances have been studied for two typical cases involving important electrochemical processes. The faradaic impedance has been interpreted quantitatively in terms of models which describe either the mass transport or the reaction mechanism at the electrode.
Epelboin, Israel, Keddam, Michel
openaire   +1 more source

Impedance spectroscopy

Annals of Biomedical Engineering, 1992
Impedance spectroscopy (IS) is a general term that subsumes the small-signal measurement of the linear electrical response of a material of interest (including electrode effects) and the subsequent analysis of the response to yield useful information about the physicochemical properties of the system.
openaire   +2 more sources

Impedance magnetocardiogram

Physics in Medicine and Biology, 2000
We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart--the so-called magnetocardiogram (MCG)--can be simultaneously detected by using this system.
A, Kandori   +4 more
openaire   +2 more sources

Impedance Cardiography

Psychophysiology, 1978
ABSTRACTThe purpose of this review was to integrate recent evidence supporting the reliability of thoracic impedance plethysmography as an estimator of cardiodynamic function. Reports regarding the development of the method for NASA, and numerous investigations comparing impedance cardiography to indicator dilution and other methods were discussed.
J C, Miller, S M, Horvath
openaire   +2 more sources

Impedance Audiometry

Annals of Otology, Rhinology & Laryngology, 1980
After a review of the development of acoustic impedance measurements, the principles of tympanometry, static compliance and measurements of the middle ear reflexes are described. The interpretation of tympanometry is done by analyzing three essential features: pressure, amplitude and shape.
openaire   +2 more sources