Results 321 to 330 of about 36,162 (357)
Some of the next articles are maybe not open access.

Mandibular implant-supported fixed dental prosthesis with a modified design: A clinical report

The Journal of Prosthetic Dentistry, 2014
This clinical report describes the rehabilitation of a patient with a mandibular implant-supported fixed dental prosthesis. Because of the limited restorative space available in the posterior mandible and in considering the higher wear rate of acrylic resin in comparison with titanium when it opposes metal ceramic restorations, the treatment used a ...
Alireza Moshaverinia   +2 more
openaire   +3 more sources

A digital technique of bone reduction for a maxillary full‐arch implant‐supported fixed dental prosthesis

Journal of Prosthodontics, 2023
AbstractWhen fabricating a maxillary full‐arch implant‐supported fixed dental prosthesis, it is often challenging to systematically reduce alveolar bone to create prosthetic space and hide the prosthesis‐tissue junction. This article presents a digital technique that allows for precise bone reduction while simultaneously placing implants and interim ...
Weimao Tang   +3 more
openaire   +2 more sources

Worn denture teeth of a full‐arch implant‐supported fixed dental prosthesis: A technique to restore

Journal of Prosthodontics, 2023
AbstractWorn denture teeth continue to be a significant complication with implant‐supported prostheses. This article discusses a case report that used an intraoral scanning system to restore an existing maxillary implant‐supported prosthesis with significant posterior occlusal wear.  IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) restorations were
Adam M. Goodrick, Sassan Nadjmi
openaire   +2 more sources

Comparison of the accuracy of implant position for two-implants supported fixed dental prosthesis using static and dynamic computer-assisted implant surgery: A randomized controlled clinical trial.

Clinical Implant Dentistry and Related Research, 2020
BACKGROUND Computer-assisted implant surgery (CAIS) can facilitate accuracy of single implant placement, but little is known with regards to parallelism between multiple implants.
Paweena Yimarj   +5 more
semanticscholar   +1 more source

CAD-CAM implant-supported fixed complete dental prosthesis with titanium milled molars: A clinical report.

The Journal of Prosthetic Dentistry, 2017
Implant-supported fixed complete dental prostheses have been associated with a high implant success rate in long-term studies. However, they have also been associated with a high frequency of prosthetic complications. The most frequent and primary prosthetic complication has been the fracture or wear of the occlusal surface of acrylic resin teeth that ...
A. AlHelal   +4 more
semanticscholar   +4 more sources

Effect of implant‐supported prosthesis on the bite force and masticatory efficiency in subjects with shortened dental arches

Journal of Oral Rehabilitation, 2013
SummaryThe aim of the study was to assess changes in bite force and masticatory efficiency in shortened dental arch (SDA) subjects rehabilitated with implant‐supported restoration for 1st molar. Ten SDA subjects with bilaterally missing mandibular molars (experimental group) were recruited.
A. Meena   +4 more
openaire   +2 more sources

Multiscale Bone Remodeling Prediction for Fully Porous-Coated (FPC) Dental Implant Supported Prosthesis [PDF]

open access: possibleAdvanced Materials Research, 2009
This paper aims at providing a preliminary understanding in biomechanics with respect to the effect of FPC dental implants on bone remodelling. 2D multi-scale finite element models are created for a typical dental implantation setting. Under a certain mastication force (<200N), a global response from a macro-scale model (without considering coated ...
Michael V. Swain   +3 more
openaire   +1 more source

Complications and patient-centered outcomes with an implant-supported monolithic zirconia fixed dental prosthesis: 1 year results.

Journal of Prosthodontics, 2014
PURPOSE To characterize the number and type of complications that occur with a monolithic zirconia fixed dental prosthesis (MZ-FDP) supported by four endosseous implants in the edentulous mandible over time and to quantify the impact of treatment on oral
Bryan Limmer   +3 more
semanticscholar   +1 more source

Effect of Inter-Implant Distance on Fracture Resistance of Implant-Supported Provisional Fixed Dental Prosthesis

Journal of Oral Implantology
This study aimed to identify the ideal interimplant distance for optimum outcome on immediately loaded implant supported prosthesis. Hence this study was taken up to analyze the effect of varying interimplant distance on fracture resistance of implant supported provisional fixed dental prosthesis (FDP).
Deepa, Balwani   +2 more
openaire   +2 more sources

A retrospective single cohort study on the 5-13 year clinical outcomes of implant-supported cross-arch fixed dental prostheses with monolithic zirconia-based frameworks.

Journal of Prosthodontics
PURPOSE To investigate the mid-to-long term clinical outcomes of the implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia-based frameworks and related risk factors of success and survival.
Jia Luo   +8 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy