Results 51 to 60 of about 2,738,408 (222)
Data for: Biomechanical Analysis of Porous Tantalum Implant Osseointegration
.txt files containing output values for hardness (gPa), elastic modulus (gPa), implant stability ...
Fraser, David
core +1 more source
Peak insertion torque (PIT); peak removal torque (PRT); implant stability quotient (ISQ) value; and implant stability test (IST ...
Lee, J (via Mendeley Data), Lee, Jungwon
core +1 more source
PCSK9 upregulation in cerebrovascular endothelial cells and microglia destabilizes the Aβ transporter LRP1, while TRIB3‐associated autophagy blockade further limits intracellular Aβ degradation. A RAP‐modified tea‐polyphenol nanoparticle co‐delivers siPCSK9 and siTRIB3 to restore LRP1‐mediated Aβ efflux and autophagy‐dependent degradation, reducing Aβ ...
Jie Miao +8 more
wiley +1 more source
Abstract Thermophilic anaerobic digestion (AD) is an attractive process due to its higher biogas yield compared to mesophilic digestion. To mitigate its higher heating demand and potential process instability, a dual‐layer control architecture comprising a decision‐making layer and an adaptive model predictive control (MPC) system is proposed.
Ali Moradvandi +3 more
wiley +1 more source
Primary implant stability is a prerequisite for successful implant osseointegration. The osseodensification technique (OD) is a non-subtractive drilling technique that preserves the bone tissue, increases osteotomy wall density, and improves the primary ...
Rafael Coutinho Mello-Machado +9 more
doaj +1 more source
Objective: Comparing the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with the linear incision technique with soft tissue preservation (LITT-P) for bone conduction devices after a follow-up of 22 months.Methods: In this ...
Ruben M. Strijbos +18 more
doaj +1 more source
Reliability and Validity of Three Instruments for Measuring Implant Stability Quotient
Background: Actually, resonance frequency analysis (RFA) is the most extended method for measuring implant stability. The implant stability quotient (ISQ) is the measure obtained by the different RFA devices, however, inter- and intra- rater reliability ...
Mónica Blázquez-Hinarejos +5 more
semanticscholar +1 more source
Fatigue‐Driven Adaptive Assistance for a Semi‐Active Upper‐Limb Occupational Exoskeleton
Physical fatigue during a physical activity is estimated in real time to enable adaptive exoskeleton assistance. By continuously adjusting the level of support according to the user’s fatigue, this approach reduces physical demand and provides a pathway toward personalized exoskeleton assistance.
Seemab Zakir +6 more
wiley +1 more source
A Modular Micro‐Chemostat System for High‐Throughput Continuous Cultivations
This study presents and demonstrates a modular 12‐channel micro‐chemostat, designed to be used by Genesis, a Robot Scientist developed to automate scientific research in yeast systems biology. The bioreactor performance fulfilled the predefined requirements, and the empirical results from the biological experiments were consistent with the literature ...
Erik Y. Bjurström +7 more
wiley +1 more source
Background: Conventionally, dental implants were placed several months after tooth extraction. Immediate implants were placed on the same day of extraction along with the conservation of the crestal bone.
Vedhavani Muthaiyan +4 more
doaj +1 more source

